Read al l instructions before using this appliance.
Save these instructions for future reference.
Page
4
LA CORNUE
Installation Guide Centenaire
08NOTINSTAL100/USA-6
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
US
A & C
AN
AD
A
u
Purchaser of this appliance must post in a prominent location instructions to
be fol lowed in the event the user smel ls gas. This information shal l be obtai-
ned by consulting your local gas supply company.
u
Keep appliance area free and clear from combustibles.
u
It is essential that the kitchen where your appliance wil l be instal led has
excel lent ventilation to the outside for steam and combustion gases removal.
u
VENTILATING HOODS:
- Clean Ventilating Hoods Frequently - Grease should not be al lowed to
accumulate on hood or filter.
- When flaming foods under the hood, turn the fan on.
u
Do not use air recycling systems.
u
“La Cornue” can provide customers with hoods in materials matching the
appliance. The hoods are sold without blower systems since every instal lation
is unique. The individual requirements are best hand led by a professional
ventilation specialist.
u
Adequate clearance must be provided for air openings into the combustion
chamber.
u
Minimum clearances to combustible construction see item 1.2. page 35.
u
Adequate clearance must be provided for proper operation and servicing of
the appliance.
u
A manual valve must be instal led in an accessible location in the gas piping
external to the appliance for the purpose of turning on or shutting off gas to
the appliance.
u
The range and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
u
The appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Summary of Contents for Grand Palais 180
Page 2: ......