The burners on the stoves of the "La Cornue" line are fitted with safety thermocouples: should a burner
extinguish, the gas supply to this burner
is automatical ly cut off.
Upon initial test of unit
When first testing the gas operated burners, you may find they do not operate.
This is normal
, and
is caused by air in the gas lines. Simply, operate each burner
starting with the top burners,
until all
the air is displaced by the gas and ignition will result. This may take 1 to 5 minutes.
On first use, the electronic safety device of the gas oven may switch on (the red indicator light goes
on).
Please press the reset button (B) until air is also displaced in the oven and the flame goes on.
1. T
ESTS
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
O
PERATION
Test
The appliance must be connected to the type of gas shown on the rating plate of the
appliance.
The gas supply line must be at least a 1/2 inch pipe.
On al l pipe joints use sealing compound that does not react to propane gas.
Check gas leaks by using a liquid leak detector.
Do not use an open flame
INSTALLER
Leave this manual with the appliance and advise the cus-
tomer to keep it for future reference.
Inform the consumer of the location of the
gas shut-off valve.
Note: Propane gas cylinders must never be
located inside your home.