Specifications
CP170
CP400
Propane Gas
Natural Gas
Propane Gas
Maximum Input (Btuh/kW)
170,000/49.8
155,000/45.4
400,000/117.2
Minimum Input (Btuh/kW)
125,000/36.6
250,000/73.3
Inlet Gas Supply
Pressure Acceptable
at the Gas Connec-
tion of the Heater
Max
11.1 in. W.C./2.74 kPa
13.5 in. W.C./3.36
kPa*
5.2 PSIG/35.74 kPa
Min
11.1 in. W.C./2.74 kPa
7.0 in. W.C./1.74 kPa*
5.2 PSIG/35.74 kPa
Burner Manifold Pressure
11.0 in. W.C./2.74 kPa
5.5 in. W.C./1.37 kPa
5.2 PSIG/35.74 kPa
Fuel Consumption
Per Hour
Max
7.89 lbs./3.57 kg
155 ft.³/4.39 m³
18.5 lbs./8.39 kg
Min
5.8 lbs./2.63 kg
125 ft.³/4.39 m³
11.6 lbs. / 5.26 kg
Motor Characteristics
1/15 H.P. / 44.7 watts
1/5 H.P. / 149 watts
3,300 RPM
Sleeve Bearing
Electrical Supply
(Volts/Hz/Phase)
120/60/1
Amp Draw
Starting
3.7
4.0
Continuous
Operation
1.0
1.3
Dimensions
Inches
24 x 10 x 16
34.5 x 12.5 x 19.5
Centimeters
61 x 25.4 x 40.6
87.5 x 31.7 x 49.5
Minimum Safe
Distances
From Nearest
Combustible
Materials (feet/
meters)
TOP
6 / 1.83
7 / 2.43
SIDES
3 / 0.9
5 / 1.52
BACK
3 / 0.9
5 / 1.52
BLOWER
OUTLET
10 / 3.05
15 / 4.57
GAS
SUPPLY
Propane Gas Supply - 6 ft./ U.S, 10 ft./3.04 m Canada
Natural Gas Supply - N/A
* The gas connection for Tradesman 170 Natural Gas heaters is the inlet of the gas
regulator supplied with the heater.