background image

1.

Do not attempt to install, repair, or service this heater
or the gas supply line unless you have continuing
expert training and knowledge of gas heaters.  

Qualifications for service and installation of this
equipment are as follows:

a. To be a qualified gas heater service person, you

must have sufficient training and experience to
handle all aspects of gas-fired heater installation,
service and repair.  This includes the task of
installation, troubleshooting, replacement of
defective parts and testing of the heater.  You
must be able to place the heater into a continuing
safe and normal operating condition.  You must
completely familiarize yourself with each model
heater by reading and complying with the safety
instructions, labels, Owner’s Manual, etc., that is
provided with each heater.

b. To be a qualified gas installation person, you must

have sufficient training and experience to handle
all aspects of installing, repairing and altering gas
lines, including selecting and installing the proper
equipment, and selecting proper pipe and tank
size to be used.  This must be done in accordance
with all local, state and national codes as well as
the manufacturer’s requirements.

2.

All installations and applications of L.B. White heaters
must meet all relevant local, state and national
codes.  Included are L.P. gas, natural gas, electrical,
and safety codes.  Your local fuel gas supplier, a local
licensed electrician, the local fire department or
similar government agencies, or your insurance agent
can help you determine code requirements.

Refer to the following:

-- CSA B149.1, Natural Gas and Propane Gas

Installation Code.

-- C S A   C 2 2 .1   P a r t   1,   S t a n d a rd   C a n a d i a n

Electrical Code and CS C22.2 No. 3, Electrical
Features of Fuel Burning Equipment.

3.

We cannot anticipate every use which maybe made of
our heaters.  Check with the local fire safety authority
if you have questions about applications.

4.

Do not wash the interior of the heater.  Use only
compressed air, a soft brush or dry cloth to clean the
interior of the heater and it’s components.

5.

For safety, this heater is equipped with manual reset
high limit switches, an air-proving switch and a
redundant gas control valve.  Never operate the
heater with any safety device that has been bypassed.
Do not operate this heater unless all of these features
are fully functioning.

6.

Do not locate fuel gas containers or  fuel supply
hoses within 6.10 meters of the blower outlet of the
heater.

7.

Do not block air intakes or discharge outlets of the
heater.  Doing so may cause improper combustion or
damage to heater components leading to property
damage.

8.

The hose assembly shall be visually inspected on a
daily basis after heater relocation and when the
heater is in use.  If it is evident there is excessive
abrasion or wear, or if the hose is cut, it must be
replaced prior to the heater being put into operation.
The hose assembly shall be protected from building
materials, and contact with hot surfaces during use.
The hose assembly shall be that specified by the
manufacturer.  See parts list.

9.

This heater is equipped with a gas selector valve.  The
selector valve must be properly positioned for the gas
supplied to the heater. Further information on this
feature is provided on page 14 of this manual.

10.

Check for gas leaks and proper function upon heater
installation, when relocating, and after servicing.
Refer to leak check instructions within installation
section of this manual.

11.

This heater should be inspected for proper operation
by a qualified service person before each use and at
least annually.

12.

Always turn off the gas supply to the heater if the
heater is not going to be used in the heating of the
work space.

13.

T h i s   h e a te r   i s   e qu i p p e d   w i t h   a   t h r e e - p ro n g
(grounding) plug for your protection against shock
hazard and must be plugged directly into a properly
grounded three-prong receptacle.  Failure to use a
properly grounded receptacle can result in electrical
shock, personal injury, or death.

14.

If gas flow is interrupted and flame goes out, do not
relight the heater until you are sure that all gas that
may have accummulated has cleared away.  In any
event, do not relight the heater for at least 5 minutes.

15.

The heater requires a minimum 1892 litre propane
tank for proper gas supply pressure and operation. A
l a r g e r   t a n k   m ay   b e   r e qu i r e d   d e p e n d i n g   u p o n
operating conditions at the site.

16.

W h e n   t h e   h e a te r   i s   to   b e   s to r e d   i n d o o r s ,   t h e
c o n n e c t i o n   b e t we e n   t h e   p ro p a n e   g a s   s u p p l y
container and the heater must be disconnected.  The
container must be reoved from the heater and stored
in accordance with the Standard CSA B149.1 Natural
Gas and Propane Gas Installation Code.

17.

Propane gas supply containers have left handed
threads.  Always use the appropriate wrench to make
a   c o n n e c t i o n   to   t i g h te n   o r   l o o s e n   t h e   p i g t a i l
connector’s  P.O.L. fitting at the container’s gas
supply valve.

6

Summary of Contents for Premier TS350

Page 1: ...29447 MODELS OUTPUT kW FUEL TS350 102 6 ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with the requirements of Standard ANSI Z83 7 CSA 2 14 and is...

Page 2: ...R SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Proper gas supply pressure must be provided to the inlet of the heate...

Page 3: ...Cleaning Instructions 14 Maintenance Instructions 14 Service Instructions General 15 Belt Replacement 15 Belt Tensioner 16 Fan and Motor Pulley 16 Drive Component Troubleshooting 16 Fan Motor 17 Air...

Page 4: ...ions and accessories commonly used on this heater When calling for technical service assistance or for other specific information always have model number configuration number and serial number availa...

Page 5: ...If there is an underground leak the movement of gas through the soil can filter the odorant Propane gas odor may differ in intensity at different levels Since propane gas is heavier than air there may...

Page 6: ...t locate fuel gas containers or fuel supply hoses within 6 10 meters of the blower outlet of the heater 7 Do not block air intakes or discharge outlets of the heater Doing so may cause improper combus...

Page 7: ...prevent injury caused from hidden leaks that could cause flashback With the main burner in operation check all connections hose connections fittings and joints as well as the gas control valve inlet...

Page 8: ...wner s Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 17 Any defects found in perfo...

Page 9: ...rely See Fig 2 5 Open the tank valve 6 Check all connections with an approved leak detector Close the tank s cover 7 When storing or transporting the heater ensure the connector s fitting is protected...

Page 10: ...NIMUM SAFE DISTANCE FROM GAS SUPPLY TO HEATER IS 6 FEET DISTANCE FROM HEATER TO SIDE WALL MUST COMPLY WITH LOCAL CODES AND BE ACCORDING TO MANUFACTURER S REQUIREMENTS MINIMUM SAFE DISTANCE FROM BLOWER...

Page 11: ...facing away from duct and are located at 3 9 and 12 o clock positions See Fig 6 3 Tighten screw clamp so adapter is held securely within duct 4 Insert tabs of adapter into slots on air diffuser back...

Page 12: ...used only when air circulation is required The heater will not cycle on its thermostat setting To discontinue the ventilation feature position the switch to off or heat C Off Position the switch to m...

Page 13: ...te on either propane or natural gas without changing out the burner orifice The gas selector valve is located between the gas control valve and the burner Gas selection is made by repositioning the va...

Page 14: ...whenever the heater is being readied for use 8 Lubricate the bearings once a month Use NLGI grade 2 mineral oil lithium or lithium base grease Maintenance Instructions 1 Before cleaning shut off all...

Page 15: ...lace the part immediately An alternate method for checking the components is to perform a continuity check 4 The air proving switch must not be jumpered If jumpered the ignition control will not allow...

Page 16: ...g guard screws Belt Dirt or grease on Remove dirt or Cracking belt or aged belt replace belt Belt wearing Belt hitting belt guard Realign guard rapidly check for loose or missing guard screws Worn pul...

Page 17: ...e motor and fan pulleys are properly aligned before tightening pulleys to motor shaft Refer to alignment procedures within manual Motor bearings are permanently lubricated 1 Remove the screws and turn...

Page 18: ...22 FIG 22 The igniter and ground rod should be cleaned during routine maintenance to maintain proper ignition Use steel wool or emery cloth Rub briskly to remove buildup of dust dirt and oxide Check...

Page 19: ...VALVE ORIFICE This heater has two limit switches One is located at the burner end of the heater The other is located on the fan housing at the motor end of the heater Their purpose is to safely shut t...

Page 20: ...T PULLEY HUB SHAFT PULLEY FLUSH WITH SHAFT END EARING RACE FLUSH WITH FRONT EDGE OF SHAFT FLAT SCREWS TIGHTENED TO FLATS SHAFT FLAT MAIN SUPPORT FAN HUB FLUSH WITH SHAFT END FAN WHEEL FAN PANEL FLANGE...

Page 21: ...with that specified on the dataplate If so then no further checking or adjustment is required Proceed to section D 3 If the inlet pressures do not agree with that specified on the dataplate then the r...

Page 22: ...onents should be replaced only after each step has been completed and replacement is suggested in the flow chart Refer to the Servicing sections as necessary to obtain information on disassembly and r...

Page 23: ...No No No No No Is Proper Voltage Supplied to Transformer No Yes Yes No See One Time Flash L E D Light is Disconnected or is Defective If Electrical Connections are Good Replace L E D Check Dataplate f...

Page 24: ...ng Switch Is Air Proving Switch Stuck Closed Check Continuity Is Airflow Switch Binding Repair Yes Yes No No Replace Air Proving Switch No Defective Wire or Loose Connection to Air Proving Switch Repa...

Page 25: ...ce Module Yes Defective Wiring or Connections to Motor Repair or Replace Wiring and Connections No Provide Proper Voltage Check Electrical Supply Circuit Breakers Etc Yes Is Fan Belt Loose No Does Fan...

Page 26: ...structions No Connect High Voltage Lead Yes A Check High Voltage Lead For Continuity and Tight Connections Replace if Defective B Defective Improperly Gapped or Dirty Igniter Replace Regap or Clean Ig...

Page 27: ...o Yes Is Proper Voltage Supplied to Selector Switch from Power Cord No VENTILATION MODE Problem Motor Hums Does Not Run Is Fan Binding on Housing Check for Damage to Motor and Fan Assembly and Housing...

Page 28: ...WHITE BLACK TERMINAL STRIP GREEN GREEN GREEN WHITE WHITE WHITE BLACK BLACK BLACK BLACK WHITE GREEN WHITE BLACK GREEN BROWN GAS CONTROL VALVE C MV WHITE BLACK POWERCORD WHITE BLACK THERMOSTAT WHITE BLA...

Page 29: ...Valve Allows easy gas conversion depending on gas being supplied at job site Eliminates the need for changeout of the burner orifice Heat Chamber Metal fire box within the appliance that provides an...

Page 30: ...50 41 45 29 28 31 49 43 44 38 51 76 55 54 14 47 48 40 39 61 18 15 66 77 68 58 59 8 10 5 47 56 57 60 65 11 12 3 6 9 16 78 20 19 2 46 70 21 47 42 1 62A 62B 43A 46 6A 68A 75 1B 15B 15A 14A 14B 5A 5B 1A...

Page 31: ...ner 02687 19 Panel Burner Access 24012 20 Chamber Heat 22890 21 Switch High Limit Burner End 325 F 81108 22 Case Assembly w Control Panel Access Door 22877 23 Panel Case Access Burner 22881 24 Panel C...

Page 32: ...54 Motor 22908 55 Pulley Motor 23038 56 Axle Wheel 22951 57 Spacer 07905 58 Hub Cap 07187 59 Wheel 22914 60 Cap Retaining 01095 61 Base 24013 62 Thermostat Kit w 20 Ft Cord 24041 62A Thermostat 09381...

Page 33: ...ate L B White equipment are free from defects both in material and workmanship for 24 months from the date of purchase by the end user Warranty is automatic if a component is found defective within 24...