MODELS

OUTPUT (kW)

FUEL

TS350                  

102.6

ATTENTION ALL USERS

This heater has been tested and evaluated by C.S.A. International in accordance

with the requirements of Standard ANSI Z83.7 

CSA 2.14 and is listed and

approved as a ductable direct gas-fired forced-air construction heater with

application for the temporary heating of buildings under construction, alteration, or

repair.  If you are considering using this product for any application other than its

intended use, then please contact your fuel gas supplier, or the L.B. White Co., Inc.

Certification by:

SCAN THIS QR CODE

with your smartphone or 
visit http://goo.gl/nvneR
to view maintenance
videos for L.B.White heaters.*

*Requires an app like QR Droid for Android or 
QR Reader for iPhone.

Summary of Contents for Premier TS350

Page 1: ...29447 MODELS OUTPUT kW FUEL TS350 102 6 ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with the requirements of Standard ANSI Z83 7 CSA 2 14 and is...

Page 2: ...R SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Proper gas supply pressure must be provided to the inlet of the heate...

Page 3: ...Cleaning Instructions 14 Maintenance Instructions 14 Service Instructions General 15 Belt Replacement 15 Belt Tensioner 16 Fan and Motor Pulley 16 Drive Component Troubleshooting 16 Fan Motor 17 Air...

Page 4: ...ions and accessories commonly used on this heater When calling for technical service assistance or for other specific information always have model number configuration number and serial number availa...

Page 5: ...If there is an underground leak the movement of gas through the soil can filter the odorant Propane gas odor may differ in intensity at different levels Since propane gas is heavier than air there may...

Page 6: ...t locate fuel gas containers or fuel supply hoses within 6 10 meters of the blower outlet of the heater 7 Do not block air intakes or discharge outlets of the heater Doing so may cause improper combus...

Page 7: ...prevent injury caused from hidden leaks that could cause flashback With the main burner in operation check all connections hose connections fittings and joints as well as the gas control valve inlet...

Page 8: ...wner s Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 17 Any defects found in perfo...

Page 9: ...rely See Fig 2 5 Open the tank valve 6 Check all connections with an approved leak detector Close the tank s cover 7 When storing or transporting the heater ensure the connector s fitting is protected...

Page 10: ...NIMUM SAFE DISTANCE FROM GAS SUPPLY TO HEATER IS 6 FEET DISTANCE FROM HEATER TO SIDE WALL MUST COMPLY WITH LOCAL CODES AND BE ACCORDING TO MANUFACTURER S REQUIREMENTS MINIMUM SAFE DISTANCE FROM BLOWER...

Page 11: ...facing away from duct and are located at 3 9 and 12 o clock positions See Fig 6 3 Tighten screw clamp so adapter is held securely within duct 4 Insert tabs of adapter into slots on air diffuser back...

Page 12: ...used only when air circulation is required The heater will not cycle on its thermostat setting To discontinue the ventilation feature position the switch to off or heat C Off Position the switch to m...

Page 13: ...te on either propane or natural gas without changing out the burner orifice The gas selector valve is located between the gas control valve and the burner Gas selection is made by repositioning the va...

Page 14: ...whenever the heater is being readied for use 8 Lubricate the bearings once a month Use NLGI grade 2 mineral oil lithium or lithium base grease Maintenance Instructions 1 Before cleaning shut off all...

Page 15: ...lace the part immediately An alternate method for checking the components is to perform a continuity check 4 The air proving switch must not be jumpered If jumpered the ignition control will not allow...

Page 16: ...g guard screws Belt Dirt or grease on Remove dirt or Cracking belt or aged belt replace belt Belt wearing Belt hitting belt guard Realign guard rapidly check for loose or missing guard screws Worn pul...

Page 17: ...e motor and fan pulleys are properly aligned before tightening pulleys to motor shaft Refer to alignment procedures within manual Motor bearings are permanently lubricated 1 Remove the screws and turn...

Page 18: ...22 FIG 22 The igniter and ground rod should be cleaned during routine maintenance to maintain proper ignition Use steel wool or emery cloth Rub briskly to remove buildup of dust dirt and oxide Check...

Page 19: ...VALVE ORIFICE This heater has two limit switches One is located at the burner end of the heater The other is located on the fan housing at the motor end of the heater Their purpose is to safely shut t...

Page 20: ...T PULLEY HUB SHAFT PULLEY FLUSH WITH SHAFT END EARING RACE FLUSH WITH FRONT EDGE OF SHAFT FLAT SCREWS TIGHTENED TO FLATS SHAFT FLAT MAIN SUPPORT FAN HUB FLUSH WITH SHAFT END FAN WHEEL FAN PANEL FLANGE...

Page 21: ...with that specified on the dataplate If so then no further checking or adjustment is required Proceed to section D 3 If the inlet pressures do not agree with that specified on the dataplate then the r...

Page 22: ...onents should be replaced only after each step has been completed and replacement is suggested in the flow chart Refer to the Servicing sections as necessary to obtain information on disassembly and r...

Page 23: ...No No No No No Is Proper Voltage Supplied to Transformer No Yes Yes No See One Time Flash L E D Light is Disconnected or is Defective If Electrical Connections are Good Replace L E D Check Dataplate f...

Page 24: ...ng Switch Is Air Proving Switch Stuck Closed Check Continuity Is Airflow Switch Binding Repair Yes Yes No No Replace Air Proving Switch No Defective Wire or Loose Connection to Air Proving Switch Repa...

Page 25: ...ce Module Yes Defective Wiring or Connections to Motor Repair or Replace Wiring and Connections No Provide Proper Voltage Check Electrical Supply Circuit Breakers Etc Yes Is Fan Belt Loose No Does Fan...

Page 26: ...structions No Connect High Voltage Lead Yes A Check High Voltage Lead For Continuity and Tight Connections Replace if Defective B Defective Improperly Gapped or Dirty Igniter Replace Regap or Clean Ig...

Page 27: ...o Yes Is Proper Voltage Supplied to Selector Switch from Power Cord No VENTILATION MODE Problem Motor Hums Does Not Run Is Fan Binding on Housing Check for Damage to Motor and Fan Assembly and Housing...

Page 28: ...WHITE BLACK TERMINAL STRIP GREEN GREEN GREEN WHITE WHITE WHITE BLACK BLACK BLACK BLACK WHITE GREEN WHITE BLACK GREEN BROWN GAS CONTROL VALVE C MV WHITE BLACK POWERCORD WHITE BLACK THERMOSTAT WHITE BLA...

Page 29: ...Valve Allows easy gas conversion depending on gas being supplied at job site Eliminates the need for changeout of the burner orifice Heat Chamber Metal fire box within the appliance that provides an...

Page 30: ...50 41 45 29 28 31 49 43 44 38 51 76 55 54 14 47 48 40 39 61 18 15 66 77 68 58 59 8 10 5 47 56 57 60 65 11 12 3 6 9 16 78 20 19 2 46 70 21 47 42 1 62A 62B 43A 46 6A 68A 75 1B 15B 15A 14A 14B 5A 5B 1A...

Page 31: ...ner 02687 19 Panel Burner Access 24012 20 Chamber Heat 22890 21 Switch High Limit Burner End 325 F 81108 22 Case Assembly w Control Panel Access Door 22877 23 Panel Case Access Burner 22881 24 Panel C...

Page 32: ...54 Motor 22908 55 Pulley Motor 23038 56 Axle Wheel 22951 57 Spacer 07905 58 Hub Cap 07187 59 Wheel 22914 60 Cap Retaining 01095 61 Base 24013 62 Thermostat Kit w 20 Ft Cord 24041 62A Thermostat 09381...

Page 33: ...ate L B White equipment are free from defects both in material and workmanship for 24 months from the date of purchase by the end user Warranty is automatic if a component is found defective within 24...