background image

Propane Vapor Withdrawal

Natural Gas

MODELS

OUTPUT

FUEL

CR125AZPA220206   

125,000 Btuh

CR125AZNA220207

( 36.6 kW)

Congratulations!

You have purchased the finest radiant construction heater available. 

Your new L.B. White heater incorporates the benefits from the most experienced

manufacturer of heating products using state-of-the-art technology.

We, at L.B. White, 

thank you

for your confidence in our products and 

welcome any suggestions or comments you may have...call us, toll-free, 

at 1-800-345-7200.

Owner's Manual and Instructions

Sun Blast

™ 

Radiant Construction Heaters

View this manual online at www.lbwhite.com

ATTENTION ALL USERS

This heater has been tested and evaluated by ETL in accordance with Standard ANSI

Z83.7

CSA 2.14 and is listed and approved as a direct fired  construction heater for

use on combustible floors.  This heater is intended for use as a portable, temporary

heater for buildings under construction, alteration, or repair.  If you are considering

using this product for any application other than its intended use, then please

contact your fuel gas supplier, or the L.B. White Co., Inc.

150-29533

SCAN THIS QR CODE

with your smartphone or 
visit http://goo.gl/nvneR
to view maintenance
videos for L.B.White heaters.*

*Requires an app like QR Droid for Android or 
QR Reader for iPhone.

4009176

Summary of Contents for CR125AZPA220206

Page 1: ...ruction Heaters View this manual online at www lbwhite com ATTENTION ALL USERS This heater has been tested and evaluated by ETL in accordance with Standard ANSI Z83 7 CSA 2 14 and is listed and approv...

Page 2: ...property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or b...

Page 3: ...o Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves the right to change...

Page 4: ...5 1 52 SIDES 5 1 52 US 6 ft 1 83 CANADA 10 3 05 N A SPECIFICATIONS CR125 Propane Natural Gas Gas Model Dimensions Inches cm L x W x H Minimum Safe Distances From Nearest Combustible Materials Feet Me...

Page 5: ...FR 1926 154 Temporary Heating Device ANSI A10 10 Safety Requirements for Temporary and Portable Space Heating Devices or the Natural Gas and Propane Installation Code CAN CSA B149 1 as appropriate Asp...

Page 6: ...ocal authority can advise you about these 8 Use only compressed air a soft brush or dry cloth to clean the heater and it s components Allow the heater to completely cool before cleaning or servicing 9...

Page 7: ...securely fastened to prevent ignition or upsetting of the heater due to wind action on the covering or other material 8 Check all connections for gas leaks using approved gas leak detectors Gas leak t...

Page 8: ...u are in doubt contact the L B White Co Inc 13 Take time to understand how to operate and maintain the heater by using this Owner s Manual Make sure you know how to shut off the gas supply to the heat...

Page 9: ...dle while the heater is operating or after the heater has been shut down can result in burns causing injury HANDLE WHEELS Assemble the wheels the the base of the heater as shown in Fig 5 Tighten secur...

Page 10: ...7 4 Keep the knob depressed for about 30 seconds to allow the thermocouple to warm up On new installations it may take a short time for gas to purge out any air before the burner lights 5 Release the...

Page 11: ...re the gas hose does not have any nicks or cuts and its connections are not corroded or have stripped threads Replace the gas hose assembly if necessary Do not repair Before each use give the heater a...

Page 12: ...lean the heater s burner and pilot orifices with compressed air or a soft dry rag Do not use files drills etc which may enlarge the holes causing combustion ignition problems Replace the component if...

Page 13: ...allowing the thermocouple to heat up for an extended period of time Normal time for thermocouple warm up is 30 seconds to 1 minute To determine if the thermocouple is defective Connect tip switch lead...

Page 14: ...e electrode check the following areas A Igniter 1 Remove the wire from the push button igniter 2 Position a screwdriver tip about 1 8 in 3 mm from igniter See Fig 14 3 Holding the screwdriver by its h...

Page 15: ...s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to section D 3 If the pressures does not agree with that specif...

Page 16: ...released Insufficient time allowed for pilot Hold in pilot button for 30 seconds to allow proper light to heat up thermocouple warm up Loose thermocouple Tighten thermocouple at gas control and make...

Page 17: ...thermocouple REGULATOR The heart of any gas supply installation Used to deliver a working pressure to the appliance under varying conditions in tank pressure SAFETY CONTROL VALVE A gas control valve w...

Page 18: ...18 Parts Identification Parts Schematic...

Page 19: ...er orifice LP gas 573281 Natural gas 573282 10 Pilot orifice LP gas 573266 Natural gas 573269 11 Thermocouple 573267 12 Pilot assembly LP gas 573268 Natural gas 573322 13 Mounting plate 573301 14 Elec...

Page 20: ...nths of the date code marked on the part If the defect occurs more than 24 months later than the date code but within 24 months from the date of purchase by the end user a copy of a bill of sale will...

Page 21: ...abrication de ses appareils de chauffage L B White tient vous remercier de la confiance que vous lui t moignez et vous invite lui communiquer tout commentaire ou suggestion sans frais au 1 800 345 720...

Page 22: ......

Page 23: ...s rieuses ou la mort MISE EN GARDE G N RALE Le non respect des mesures de pr cautions ainsi que des directives d utilisation de cet appareil telles que d crites dans ce manuel peut entrainer La mort...

Page 24: ...de l appareil ainsi que son num ro de s rie Vous trouverez cette information sur la fiche signal tique de l appareil Ce manuel vous renseigne sur la fa on appropri e d utiliser et de maintenir votre a...

Page 25: ...nimales de d gagement des mati res combustibles environnantes M tres Consommation de combustible l heure Combustible Pression au manifold du br leur kPa Sp cifications SPECIFICATIONS CR125 Gaz Gaz Pro...

Page 26: ...ce de gaz chapp S assurer que ceux ci a rent convenablement l immeuble avant d y retourner S assurer que la fuite est colmat e et r par e par du personnel qualifi Bien s assurer que la fuite a bel et...

Page 27: ...ns particuli res 7 Il existe d autres normes et codes qui r gissent l utilisation d appareils au gaz dans certaines circonstances et applications particuli res S en informer aupr s des autorit s de vo...

Page 28: ...lorsqu il est chaud ou en op ration en plus d tre une distance s curitaire de mat riaux combustibles tels que murs planchers ou plafonds Ne pas placer d objets pouvant devenir combustibles l int rieur...

Page 29: ...les fuites ont t identifi es et colmat es avant de continuer d op rer l appareil 9 Une v rification de la pression du gaz doit tre effectu e par le repr sentant d une autorit comp tente en la mati re...

Page 30: ...venir tout dommage et d emp cher que des salet s ne p n trent dans le r gulateur R gulateur de gaz naturel Pression d entr e maximale 3 36 kPa Pression d entr e minimale 1 74 kPa Brancher le r gulate...

Page 31: ...se de la poign e pendant que l appareil de chauffage fonctionne ou apr s son arr t peut entra ner des br lures POIGN E ROULETTES Monter les roues pour le chauffage comme illustr la figure 5 Bien serre...

Page 32: ...leuse Consulter la figure 8 FIG 7 4 Maintenir la pression sur le bouton environ 30 secondes pour permettre le r chauffement du thermocouple Il faut noter que sur des installations r centes il peut s c...

Page 33: ...le radiateur doivent tre d gag s et libres de toute mati re combustible d essence et d autres vapeurs et liquides inflammables 2 Le r gulateur doit tre inspect de temps autre afin d assurer que l vent...

Page 34: ...nne bien V rifier s il y a pr sence de fuites de gaz 5 Nettoyer le l orifice de l appareil de chauffage avec de l air comprim ou un chiffon doux et sec Ne pas utiliser de lime de perceuse ou autre pou...

Page 35: ...as fait la veilleuse pourrait s teindre Lors de la connexion du thermocouple la valve de contr le visser celui ci d abord la main puis une fois bien en place avec une cl molette FIG 13 BARILLET D ORIF...

Page 36: ...Retirer le fil reli au bouton poussoir de l allumeur 2 Placer la pointe d un tournevis une distance d environ 3 mm po de l allumeur Consulter la figure 14 3 En tenant le tournevis par sa poign e appu...

Page 37: ...pression coincident elles avec la fiche signal tique Si oui aucune autre v rification ou ajustements ne sont n cessaires Veuillez vous rendre directement la section D 3 Si les lectures de pression ne...

Page 38: ...nir la pression sur lebouton poussoir de contr le rel ch e r chauffer ad quatement le pendant 30 secondes pour permettre un r chauffement thermocouple appropri Thermocouple desserr Serrer ad quatement...

Page 39: ...ermocouple Fonctionne directement et simultan ment avec le thermocouple R GULATEUR La pi ce ma tresse de tout syst me aliment au gaz Utilis pour fournir une pression de gaz appropri e l appareil sous...

Page 40: ...19 Sch ma des pi ces composantes Identification des pi ces composantes...

Page 41: ...Propane 573281 Gaz naturel 573282 10 Orifice de la veilleuse Propane 573266 Gaz naturel 573269 11 Thermocouple 573267 12 Assemblage de la veilleuse Propane 573268 Gaz naturel 573322 13 Plaque de fixat...

Page 42: ...s av rait d fectueuse l int rieur d une p riode de 24 mois d butant la date code inscrite sur ladite pi ce Si la d fectuosit survient plus de 24 mois apr s la date code mais n anmoins l int rieur d un...

Reviews: