10
Start-Up Instructions
1.
Slowly open the fuel supply valve at the propane gas
supply. (This prevents lockup of the excess flow check
valve internal to the regulator’s POL fitting.)
2.
Fully depress the button on the safety control valve
while pushing the piezo igniter button. The burner will
light. See Fig. 6.
FIG. 6
3.
Keep the safety control’s button depressed for about
30 seconds to allow the thermocouple to warm up.
■
On new installations it may take a short time for
gas to purge out any air before the burner lights.
4.
Release the safety control’s button. The burner will
stay lit.
Shut-Down Instructions
1.
Close all fuel gas supply valves.
2.
Allow the heater to burn off any fuel gas remaining in
the gas supply line.
3.
Disconnect the heater from its gas supply.
PIEZO IGNITER
BUTTON
SAFETY CONTROL
BUTTON