Loudspeaker congurations
Pre-alignment delays
presets
pre-alignment delay values and polarity settings
[X8] + [SB15_100]
X8 = 2 ms
SB15m = 0 ms
[X8] + [SB15_100_C]
X8 = 5.7 ms
SB15m = 0 ms
[X8] + [SB15_100_Cx]
X8 = 3.8 ms
SB15m = 0 ms
X8 stage monitor
Deployed as a stage monitor, an X8 system operates over the nominal bandwidth of the X8 enclosure.
The [X8_MO] preset delivers a reference frequency response in stage monitoring applications.
The X8 enclosure is driven by the LA4X / LA8 / LA12X.
Standalone X8
35°
Enclosure X8
Preset [X8_MO]
Frequency range (-10 dB) 55 Hz - 20 kHz
Low-latency preset
A low-latency preset is available for the X8 enclosure used as a monitor ([X8_MO]). It reduces latency from 3.84 ms
down to 1.18 ms (LA8) and 0.84 ms (LA4X / LA12X). If the monitor is combined with a subwoofer, a custom preset must
be used.
Paired X8 monitors with LFC
The Low Frequency Contour (LFC) tool implemented in LA Network Manager can compensate for coupling effects
between closely operating monitors. LFC allows to adjust the frequency response curve to obtain the desired low
frequency contour.
For paired X8 monitors, enter the following parameters to obtain the reference response curve of a single enclosure:
-3.0
180
For more information about LFC, refer to the
LA Network Manager Help
(section: Group Control Panel) and to the
Array Morphing
.
X8 owner's manual (EN) version 1.0
25