Mechanical safety
Mechanical safety
The X8 rigging system complies with EN 62368-1: 2014 Audio/video, information and communication technology
equipment — Part 1: Safety requirements.
The deployments described in this manual achieve a safety factor of
5
.
X8
Conguration
Rigging accessory
Maximum / Safe limit
X-US8 / X-UL8 + X-UTILT (optional)
1
Wall-mounted
X-UL8i
1
Ceiling-mounted
X-US8 / X-UL8 / X-UL8i
1
Flown
X-US8 / X-UL8 / X-UL8i / X-BAR +
CLAMP250 (optional)
1
Pole-mounted
35 mm pole
+ EMBi and X-US8 (optional)
1
Ground-stacked
No rigging accessory
1
Additional safety for own arrays
When ying an enclosure, use the M8 DIN580 threaded insert to implement a secondary safety.
22
X8 owner's manual (EN) version 1.0