Installation
Connecting to AC mains
Electrical specications
AC mains specications
Verify the electrical conformity and compatibility of the mains supply.
Only connect the product to an AC power outlet rated 100-240 V, 50-60 Hz.
The product draws 150 W (typical).
WARNING: The product is of Class 1 construction and shall be connected to a mains socket outlet with a
Protective Earth connection.
Three-phase circuit
When the product is used in a three-phase circuit, verify the electrical conformity and
compatibility of the three-phase circuit.
Verify that the three phases work, and balance the loads between the three phases.
Verify that the neutral and earth work.
Never try to emulate a 230 V circuit connecting an apparatus to two live wires of a 120 V three-phase circuit.
Never try to emulate a 200 V circuit connecting an apparatus to two live wires of a 100 V three-phase circuit.
Power cord
The removable power cord is tted with a V-Lock compatible IEC connector at one end, and a country-specic plug at the
other end.
type
plug
cable ratings
live
neutral
ground
CE
CEE7/VII, earthed
CN
GB 2099, earthed
INT
bare ends (local power
plug to be tted)
10 A / 250 V
brown
blue
green/yellow
US
NEMA 5-15, earthed
10 A / 125 V
black
white
green
Strictly apply the specic safety regulations of the country of use.
Do not defeat the ground connection of the supplied power cord using an adaptor or any other methods.
A suitable plug must be wired to the INT power cord.
Verify that the plug conforms to the specic voltage and current rating given in section
(p.22).
22
L-ISA Processor II owner's manual (EN) version 1.0