Mechanical safety
Mechanical safety
Flown congurations
The A15i rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines
of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of
4 or more
.
Refer to Soundvision for the safety factor of a specic deployment.
The
safe limit
gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-enclosure angles, etc.).
The
maximum limit
gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
A15i Wide/Focus
conguration
rigging accessory
maximum / safe limit
A15i-BUMP + rigging M-BARi (optional)
8
A15i-RIGBAR x2 + rigging plates
4
A-U15i
1
Vertical array
A-U15i + A15i-ULINK
2
1 × A15i-LIFT
1 or 3
2 × A15i-LIFT
2, 4, 5 or 6
Radial array
3 × A15i-LIFT
7, 8 or 9
A-U15i
1
Wall-mounted (horizontal)
A-U15i + A15i-ULINK
2
Wall-mounted (vertical)
A-U15i
1
Ceiling-mounted
A-U15i + A15i-ULINK
or Ai-FIXBRACKET/A15i-TILTB rigging plates
2
KS21i
conguration
rigging accessory
safe limit
maximum limit
A15i-BUMP + rigging plates
8
16
A15i-RIGBAR x2 + rigging plates
4
A-U15i
1
Vertical array
A-U15i + KS21i-ULINK
2
A-U15i
1
Wall-mounted
(horizontal)
A-U15i + KS21i-ULINK
2
Wall-mounted (vertical)
A-U15i
1
Ceiling-mounted
A-U15i + KS21i-ULINK
or Ai-FIXB rigging plates
2