Rigging procedures
Wall-mounting or ceiling-mounting
Mounting an assembly with A-U15i
Type of deployment
ceiling-mounting, wall-mounting
Rigging accessories
A-U15i
U-bracket rigging plates
Additional accessories
M8x35 rigging screws (provided)
4 x M10 screws and anchors
T40 Torx bits
Min number of operators
3
Rigging plates
x2
x2
x2
A15i-ULINK
Rigging plates
for ying two
A15i with A-U15i
A15iKS21i-ULINK
Rigging plates for
ying A15i under
KS21i with A-U15i
KS21i-ULINK
Rigging plates
for ying
two KS21i
with A-U15i
Additional safety for own arrays
When ying an array, use available holes to implement a secondary safety.
The procedure is shown with A-U15i in horizontal position.
The same procedure applies for all congurations with A-U15i. Refer to
APPENDIX B: Congurations with A-U15i
(p.113).
Resistance value of anchoring points
Conguration
Tensile load
Shear load
A-U15i in horizontal position, with 1 enclosure
275 daN
65 daN
A-U15i in horizontal position, with 2 enclosures
375 daN
75 daN
Wall-mounted
A-U15i in vertical position, with 1 enclosure
40 daN
30 daN
Ceiling-mounted
150 daN
—