SPA EQUIPPED SAFETY DEVICES
Your spa is equipped with the following safety features:
1.
Overheat Protection
– A water temperature sensor circuit in the system will monitor the water
temperature. If the temperature reaches 112°F (44°C), the pump and all accessories will shut off.
The spa will resume normal operation when the water temperature drops to 109°F (42°C).
2.
Heater High Limit Protection
– If the water temperature reaches 119°F (48°C) as determined by
the water temperature sensor circuit, the pump and all accessories will shut off. The spa will
resume normal operation when the water temperature drops to 109°F (42°C) and a key press to
clear the fault.
3.
Heater Dry Run Protection
– The system will prevent the heater from turning on if it determines
that there is not enough water flow to operate the heater.
4.
Freeze Protection Mode
– The freeze protection system will activate at 44°F (6.6°C). The system
will turn on the low speed pump and heat to the set temperature. The spa will resume normal
operation upon reaching a temperature of 45°F (7.2°C).
5.
Timeouts
– The pump will turn off automatically after 40 minutes of continuous operation. The
lights will turn off automatically after 1 hour of continuous operation.