28
rev. 2011-5-26
DIAGNOSTIC MESSAGES
(continued)
Message Description
Corrective
Action
PRIMING MODE
TAKES 4 MIN
Spa goes to priming mode during the
initial start-up.
See Initial Start-Up Instructions section
(page 13).
--F
or
--C
Temperature unknown.
After the spa pump has been running
for 1 minute, the temperature will be
displayed.
----
Temperature not current in Economy or
Sleep mode.
In Economy or Sleep mode, the spa
pump maybe off for hours outside of a
filter cycle. To display the current
temperature, either switch to Standard
mode or turn on spa pump for at least 1
minute.
Standby mode
Standby mode has been activated by
pressing a key combination on the
control panel.
Press any key to leave Standby mode
and return to normal operation.
Ph is low
raise ph
pH is low.
Add pH increaser accordingly. See the
Water Balance section.
Ph is high
lower ph
pH is high.
Add pH reducer accordingly. See the
Water Balance section.
Sanitizer low
Sanitizer is low.
Add sanitizer accordingly. See the
Water Balance section.
Sanitizer high
Sanitizer is high.
Remove spa cover and allow sanitizer
to dissipate.
Draining
Spa pump is on during Standby mode to
assist in draining the spa.
Press Spa Jets key to turn off the spa
pump when water has drained. Power
off spa.
Rtc failure
Hardware failure.
Call for service.
Persist fail
Hardware failure.
Call for service if message appears on
more than one power up.
Chksum fail
Firmware install problem.
Call for service if message appears on
more than one power up.
Config error
Configuration error. Spa cannot start
up.
Call for service.
Gfci failure
Spa could not trip GFCI.
Call for service. Continued operation
maybe unsafe.
Stuck on
A pump appears to be stuck on, causing
the water temperature to creep up,
possibly to hazardous levels.
POWER DOWN SPA IMMEDIATELY.
DO NOT ENTER THE WATER. Call for
service.
Hot-call svc
A pump appears to have been stuck on
the last time spa was powered.
POWER DOWN SPA IMMEDIATELY.
DO NOT ENTER THE WATER. Call for
service.