18
rev. 2012v1
In order to warn the user, the spa light will flash for a few seconds before the exit of the Standby mode.
ECONOMY MODE
The economy mode is used to reduce power consumption when the spa is not in use. In economy
mode, the heater will only engage when the water reaches a temperature equal to 20°F (11°C) below
the set temperature during a certain period of the day. The factory default period is from midnight to
6AM. If a different period is desired, please refer to the Programming the Control System section for
programming instructions.
While the Economy mode is engaged, the display will toggle between
Eco
and the water temperature.
The Economy mode can be cancelled by pressing and holding the
On/Off
key for 5 seconds.
The Economy mode can be manually enabled immediately outside the pre-programmed period. It will
stop at its next programmed stop time. Press and hold the
On/Off
key for 5 seconds to manually enable
the Economy mode.
FILTRATION SYSTEM
The spa is factory programmed to filter two times a day for 1 hour. In most cases, this is sufficient
filtration. However, the number of cycles can be modified between 1-4 cycles per day, and the cycle
duration can be modified between 0-6 hours per cycle in increments of 1 hour. Refer to the
Programming the Control System section for programming instructions.
Filter cycles occur in two steps: a purge and a clean step. During the purge step, typically, all pumps
are turned on for one minute to purge the spa plumbing. For the remainder of the filter cycle, pump #1
low speed will operate to perform the clean step.
The filtration cycle can be suspended by pressing any of the jet keys. The filtration icon will blink on the
control panel display. The filtration cycle will resume after 40 minutes from the last key press.
PROGRAMMING THE CONTROL SYSTEM
1. Clock:
Press and hold the
Program
key for 5 seconds to engage the programming mode. Then press the
Up
or
Down
arrow key to change the hour setting. Once the desired hour is displayed, press the
Program
or
OK
key to accept the selection, and move to programming the minute setting. Use the
Up
or
Down
arrow key to change the minute setting. Once the desired minute is displayed, press
the
Program
or
OK
key to accept the selection and move to programming the filter cycle start time.
2.
Filter Cycle Start Time:
To set the start time of the filter cycle, press and hold the
Program
key to initiate the programming
mode. Then press the
Program
key twice to access the filter cycle start time programming. Press
the
Up
or
Down
arrow key to cycle through the hour between 0 and 23 in increments of 1 hour.
Program default setting is 12, which depicts 12PM start time. For a midnight start time, select 0.
Once the desired start time is displayed, press the
Program
or
OK
key to accept the selection and
move to programming the filter cycle duration.
3.
Filter Cycle Duration:
To set the duration of each filter cycle, press and hold the
Program
key to initiate the programming
mode. Then press the
Program
key three times to access the filter cycle duration programming.
Press the
Up
or
Down
arrow key to cycle through 0-24 hours in increments of 1 hour. Program
default is 1 hour. Once the desired duration is displayed, press the
Program
or
OK
key to accept