27
Symptom and Solution Troubleshooting
Use the following checklist when you encounter
problems with your camera. If the problem can not be
corrected, consult an authorized L-3 CIP dealer.
Symptom Cause/Remedy
Camera does not turn
on.
Battery improperly installed.
Remove battery and install
correctly.
Battery charge is low. Replace with
fully charged battery.
Battery well terminals are dirty or
corroded. Clean battery well
terminals.
Camera turns off
during operation.
Battery charge is low. Replace with
fully charged battery.
Battery icon appears
on menu.
Battery charge is low. Replace with
fully charged battery.
Poor battery
performance.
Battery needs refreshing. Refresh
battery 2 to 3 times using refresh
button on charger (NiCd batteries
only).
Battery defective. Replace battery.
Low contrast or no
image in viewfinder.
Gain, Level, or Bright set too low.
POWER switch is in STANDBY.
Move POWER switch to ON
position.
Condensation on eyepiece. Clean
eyepiece on viewfinder.
Condensation on front lens. Place
camera in a dry area at room
temperature until condensation
evaporates.
Manual iris rotated fully clockwise,
i.e. closed (25mm and 50mm lenses
only).