INSTRUMENT LAYOUT

Clamp Sensor

Pick up current flowing through the conductor.

Barrier (Protective figerguard)

It is a part providing protection 

against electrical shock and ensuring the minimum required air 

and creepage distances.

A Zero Adjust Button

Used for zero adjustment on DCA. Also used 

to reset the display resding.

Data Hold Button

Freezes the display reading.

Function Selector Switch

Selects function. Also used to power the 

instrument on.

Range Selector Button

Selects measuring mode. When the 

Ω

 range the defaults to the Resistance. Then, press this 

switch to cycle through Resistance 

 Diode 

 Cotinuity 

 

Capacitor 

 Resistance. When the 60A, 120A range the 

defaults to the AC. Then, press this switch to cycle through AC 

 DC 

 AC.

Test Lead Cap

Test leads can be used under the CAT.II and III 

environments by attaching a Protective cap as illustrated 

below. Use of our Protective cap offers different lengths 

suitable for the test environments.

#

 

CAUTION

 The Cap should be firmly attached to the Probes.

5

PREPARATIONS FOR MEASUREMENT

1

Checking battery voltage

  

 Set the Function Selector Switch to any position other than 

the OFF position. If the marks on the display is clearly legible 

without symbol " 

 " showing, battery voltage is OK. 

If the display blanks or " 

 " is indicated, replace the 

batteries according to section 8: Battery Replacement.

NOTE

 When the instrument is left powered on, the auto-power-save 

function automatically shut the power off; The display blanks 

even if the Function Selector Switch is set to a position other 

than the OFF position in this state.

 To power on the instrument, turn the Function Selector Switch 

or press any Button. If the display still blanks, the batteries are 

exhausted.

   Replace the batteries.

2

 Make sure that the Function Selector Switch is set to the 

appropriate range.

  

 Also make sure that data hold function is not enabled. If 

inappropriate range is selected, desired measurement 

cannot be made.

3

 Permits the measurement by placing the 

one test lead in the holster while confirming 

the measurement value.

#

 

WARNING

 Verify proper operation on a known source before use or taking 

action as a result of the indication of the instrument.

Adjust Button

Clamp Sensor

Barrier

A Zero

Clamp Sensor

Cable

Function Selector Switch

Data Hold

Button

Range Selector

Button

 

    Button

 

    Button

Holster

LCD Display

Test Lead

Protective fingerguard

Test Lead Cap

Continuity

Capacitor

Diode

Resistance

DC

AC

・・・・

Resistance

60A, 120A

・・・・

AC

default setting

Battery Voltage

AC / DC

Continuity

Data Hold

Bar Graph

Unit

Zero ADJ

Diode Test

Buzzer

Warning

Protective Cap

Exposed metal part

Uncapped condition for CAT.II environment

Capped condition for CAT.III environments

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for KEW MATE 2012RA

Page 1: ...DIGITAL MULTIMETER WITH AC DC CLAMP SENSOR KEW MATE 2012RA www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...his instrument has been designed and tested according to IEC Publication 61010 Safety Requirements for Electronic Measuring Apparatus This instruction manual contains warnings and safety rules which m...

Page 3: ...omes standard with the instrument Clamp sensor for ease of use in crowded cable areas and other tight places Permits current measurement with an open current clamp sensor that does not require opening...

Page 4: ...Input Voltage 600V Range Display range Allowable input Accuracy 600mV 0 0 603 9mV 0 0m 600 0V 1 0 rdg 3dgt 6V 0 560 6 039V 60V 5 60 60 39V 600V 56 0 603 9V Input Impedance approx 10M Resistance Auto...

Page 5: ...g System modulation Display Liquid crystal display Maximum Reading 6039 Except Hz 9999 CAP 4039 Diode 1999 Bar graph with maximum points of 30 Display approx 3 times per second Indication renewal Loca...

Page 6: ...the batteries according to section 8 Battery Replacement NOTE When the instrument is left powered on the auto power save function automatically shut the power off The display blanks even if the Functi...

Page 7: ...LCD 2 Adjust one of the conductors to the center of the clamp sensor s arrow When the position of the conductor is not at the center of the arrow the error occurs Measured value is shown on the displa...

Page 8: ...urement DANGER In order to avoid possible shock hazard never make measurement on circuits with a maximum voltage difference of 600V or greater between conductors 300V or greater between a conductor an...

Page 9: ...Turn the function switch to the OFF and then to any position 7 2 Data Hold Function This is a function to freeze a measured value on the display Press the Button once to hold the current reading In t...

Reviews: