OTHER FUNCTIONS

7-1 Auto-Power-Save Function

NOTE

 A small amount of current is consumed even in the power-save 

state. Make sure to set the Function Selector Switch to the 

OFF position when the instrument is not used.

This function helps to avoid unwanted exhaustion of the batteries 

because of leaving the instrument powered on and extend battery 

life.

The instrument automatically shifts to the power-save state about 

15 minutes after the last Function Selector Switch or other switch 

operation.

A minute before power-save mode the instrument beeps 5 times, 

finally beeps longer and then shifts to the power-save mode.

To return to the normal state:

Press the 

 Button or the 

SEL

 Button to return from the 

power-save mode state to the normal state.

Note:

 Pressing  the 

 Button or the 

SEL

 Button over 2 sec 

to return from the power-save mode state, the function of 

each button is also enabled.

             (ex.)  When  the  function  is  60A  and  in  the  power-save 

mode, pressing 

SEL

 Button over 2sec releases the 

power-save mode and changes from initial  AC  mode  to 

DC  mode. 

To cancel the Auto-Power-Save Function

       To cancel the Auto-Power-Save Function, turn the function 

switch from OFF position to any other position with pressing 

SEL

 Button.

Note:

 When the function switch is 60A or 120A, pressing A 

ZERO ADJ Button over 2 sec enables to cancel the Auto-

Power-Save Function. 

            In this case, pressing A ZERO ADJ Button over 2 sec once 

agin enables the Auto-Power-Save Function. 

To enable the Auto-Power-Save Function once again

     Turn the function switch to the OFF, and then to any position.

7-2 Data Hold Function

This is a function to freeze a measured value on the display. 

Press the 

 Button once to hold the current reading. In this 

data hold state, the reading is held even if input varies. "   " 

mark is shown on the LCD. To exit the data hold state, press the 

 Button again.

Note:

 Data Hold Function is not effective while making 

Continuity or Diode measurement.

  

 

 When the function is on the position where 

SEL

 Button or 

A ZERO ADJ Button is effective, pressing 

SEL

 Button or 

A ZERO ADJ Button cancels the held indication.

8

BATTERY REPLACEMENT

#

 

WARNING

 In order to avoid possible shock hazard, always disconnect 

the test leads from the circuit under test and set the Function 

Selector Switch to the OFF position before trying to replace the 

batteries.

#

 

CAUTION

Do not mix new and old batteries.

 Install batteries in the orientation as shown inside the battery 

compartment, observing correct polarity.

When the battery voltage warning mark " 

 " is shown on the 

top left corner of the LCD, replace the batteries. Note that the 

display blanks and " 

 " mark is not shown if the batteries are 

completely exhausted.

(1) Set the Function Selector Switch to "OFF."

(2) Remove the instrument from the holster.

(3)  Loosen the battery-compartment-cover-fixing screw on the 

lower back of the instrument.

(4) Replace the batteries with two new R03 (UM-4) 1.5V batteries.

(5)  Put the battery compartment cover back in place and tighten 

the screw.

 [ How to storage the clamp sensor and the test leads ]

Battery

Compartment

Cover

Batteries

Screw

Wind the lead around the folder.

Test Leads

Clamp Sensor

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for KEW MATE 2012RA

Page 1: ...DIGITAL MULTIMETER WITH AC DC CLAMP SENSOR KEW MATE 2012RA www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...his instrument has been designed and tested according to IEC Publication 61010 Safety Requirements for Electronic Measuring Apparatus This instruction manual contains warnings and safety rules which m...

Page 3: ...omes standard with the instrument Clamp sensor for ease of use in crowded cable areas and other tight places Permits current measurement with an open current clamp sensor that does not require opening...

Page 4: ...Input Voltage 600V Range Display range Allowable input Accuracy 600mV 0 0 603 9mV 0 0m 600 0V 1 0 rdg 3dgt 6V 0 560 6 039V 60V 5 60 60 39V 600V 56 0 603 9V Input Impedance approx 10M Resistance Auto...

Page 5: ...g System modulation Display Liquid crystal display Maximum Reading 6039 Except Hz 9999 CAP 4039 Diode 1999 Bar graph with maximum points of 30 Display approx 3 times per second Indication renewal Loca...

Page 6: ...the batteries according to section 8 Battery Replacement NOTE When the instrument is left powered on the auto power save function automatically shut the power off The display blanks even if the Functi...

Page 7: ...LCD 2 Adjust one of the conductors to the center of the clamp sensor s arrow When the position of the conductor is not at the center of the arrow the error occurs Measured value is shown on the displa...

Page 8: ...urement DANGER In order to avoid possible shock hazard never make measurement on circuits with a maximum voltage difference of 600V or greater between conductors 300V or greater between a conductor an...

Page 9: ...Turn the function switch to the OFF and then to any position 7 2 Data Hold Function This is a function to freeze a measured value on the display Press the Button once to hold the current reading In t...

Reviews: