11
. CRANKCASE/CRANKSHAFT
11-6
VITALITY 50
Measure the crankshaft runout.
Service Limit
A
B
0.150mm
replace if over
0.100mm
replace if over
Check the crankshaft bearings for excessive
play. The bearings must be replaced if they
are noisy or have excessive play.
CRANKSHAFT INSTALLATION
Wash the crankshaft in cleaning solvent and
then check for cracks or other faults.
•
After check, apply clean engine oil to
all moving and sliding parts.
•
Remove all gasket material from the
crankcase mating surfaces. Dress any
roughness or irregularities with an oil
stone.
Axial
Play
Play
Radial
Summary of Contents for Vitality 50
Page 20: ...2 GENERAL INFORMATION 2 15 VITALITY 50 WIRING DIAGRAM 2 STROKE ...
Page 21: ...2 GENERAL INFORMATION 2 16 VITALITY 50 WIRING DIAGRAM 4 STROKE ...
Page 47: ...2 GENERAL INFORMATION 2 42 VITALITY 50 Faulty ignition coil ...
Page 66: ...4 LUBRICATION SYSTEM 4 1 VITALITY 50 LUBRICATION SYSTEM 2 STROKE ...
Page 92: ...6 4 STROKE CYLINDER HEAD VALVES 6 1 VITALITY 50 ...
Page 108: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 2 VITALITY 50 4 STROKE ...
Page 150: ...10 FINAL REDUCTION 10 1 VITALITY 50 ...
Page 159: ...11 CRANKCASE CRANKSHAFT 11 1 VITALITY 50 2 STROKE Torque 0 8 1 2kg m ...
Page 160: ...11 CRANKCASE CRANKSHAFT 11 2 VITALITY 50 4 STDROKE ...
Page 173: ...12 CARBURETOR 12 1 VITALITY 50 ...
Page 259: ...16 ELECTRICAL EQUIPMENT 16 17 VITALITY 50 ELECTRIC STARTER Starter Motor Starter Relay ...
Page 263: ...16 ELECTRICAL EQUIPMENT 16 21 VITALITY 50 ...
Page 275: ...18 SPECIFICATIONS 18 1 4 STROKE ...