KIEN6000T Industrial Ethernet Switch User’s Manual
Kyland Telecom
-
18
-
F
ON
redundant mode; the unit is
set as central office devices
T
ON
1 2
ON
T
F
1 2
ON
T
F
F
ON/OFF
Optical fiber interface is in
common connection mode.
Attention:
In an optical fiber redundant ring network, only one end equipment should be set as
local, and others as remote.
3.2.4 Bottom panel
There is a threaded hole for grounding in the bottom panel of
KIEN6000T. M3×8
screw and
Ф
3 cold pressed terminal for grounding free of charge will be delivered
together with the main unit. As shown in Figure 3-8, crimp one end of grounding
conductor to the cold pressed terminal and then use the grounding screw to fix it at the
grounding hole of the shell; reliably connect the other end of grounding conductor to
the ground. The diameter of grounding cable should be less than 2mm.