KYLAND KIEN6000T User Manual Download Page 13

 

 

-

5

Chapter 2 Performance Indexes

 

2.1 System indexes 

The system performance indexes of KIEN6000T industrial Ethernet switch are shown 

in Table 2-1.   

Table 2-1 System Indexes

 

System Indexes 

KIEN6000T 

Quantity of RJ45 port 

10Base-T/100Base-TX 

Quantity  of  uplink  redundant 

fiber port 

2 x 100Base-FX-SM/MM 

System parameters   

Supporting  standard:  IEEE802.3,  IEEE  802.3x,  IEEE  802.3u, 

IEEE 802.1p, IEEE 802.1Q 

Store-and-Forward speed: 148810   pps 

Max. filtering speed: 148810    pps 

Switching mode: Store-and-Forward 

Switching bandwidth of system: 4.8G 

Max. VLAN quantity: 16 

Electromagnetic compatibility interference:       

EN55022 

Electromagnetic compatibility immunity: EN50082-2 

Ethernet port   

Physical port: shielded RJ-45 

RJ-45  port:  10Base -T/100Base-TX,  supporting  automatic 

negotiation function 

Port standard: in line with IEEE802.3 standard 

Transmission distance: <100m 

Fiber port 

Radiation power: >-13dbm(SM)    >-20dbm(MM) 

Receiving sensitivity: <-28dbm(SM) 

<-35dbm(MM) 

Wave length: 1310nm(SM)    1550nm(SM)    1310 nm(MM) 

Transmission distance: 20

80Km(SM)      <2Km(MM)  

Connector type: SC/FC 

Transmission rate: 125Mbps 

CONSOLE interface 

Physical interface: shielded RJ-45 

Interface standard: in line with RS232 standard (3 lines) 

Interface speed: 19200bps 

Power supply 

Input voltage: double channelDC24V

DC 18V

36V

 

Input power consumption: <6W 

Overcurrent protection: built-in   

Mechanical parameter 

Physical  dimensions  (height

width

depth):  142

55.4

Summary of Contents for KIEN6000T

Page 1: ...KIEN6000T Industrial Ethernet Switch User s Manual KYLAND Telecom Technology Co Ltd...

Page 2: ...d or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Telecom Technology CO LTD Address 5 F Office Building Transport Center East of X...

Page 3: ...installation and commissioning network management etc to provide users with references in startup expansion and routine maintenance It is a practical teaching material that can be used by users in tra...

Page 4: ...s of KIEN6000T industrial Ethernet switch Appendix C introduces abbreviations used in this manful Statement as product and technology upgrades and improves constantly the contents of this document may...

Page 5: ...other equipments should be firmly interconnected and frequently checked In the following cases please immediately disconnect the power supply and contact with our company 1 Water gets into the equipme...

Page 6: ...users during operation The implications of these signs are as follows Warning pay special attention to the notes behind the mark improper operation will result in serious damage of the switch or injur...

Page 7: ...e 9 3 2 1 Case 9 3 2 2 Front panel 11 3 2 3 Top panel 14 3 2 4 Bottom panel 18 Chapter 4 Hardware Mounting 21 4 1 Mounting requirements 21 4 2 Main unit mounting 21 4 2 1 Rail mounting 21 4 2 2 Wall m...

Page 8: ...ii 6 1 Networking mode 33 6 2 System configuration 35 Appendix A Twisted pair and Pin Distribution 37 Appendix B Cable Type and Specifications 39 Appendix C Glossary 41...

Page 9: ...rovides two mounting ways DIN rail and wall mounting On the front panel there are two pairs of uplink redundant 100Base FX single mode or multi mode optical fiber interfaces The uplink optical fiber i...

Page 10: ...vidual naming for each devices in the network 4 Setting and query of VLAN 5 Setting and query for alarm of power and ports link 6 Setting and query for port working mode prioritization and rate Indust...

Page 11: ...0T from falling apart after opening the case If a hard object is used to unclench the case do not overly extend the hard object into the case to avoid damage of the equipments inside the case After op...

Page 12: ......

Page 13: ...ference EN55022 Electromagnetic compatibility immunity EN50082 2 Ethernet port Physical port shielded RJ 45 RJ 45 port 10Base T 100Base TX supporting automatic negotiation function Port standard in li...

Page 14: ...state and automatically working in full duplex or half duplex operation mode supporting automatic MDI MDI X connection The transmission distance is less than 100m 2 Two pairs of uplink redundant 100B...

Page 15: ...Cut Through and Store and Forward In Cut Through a data packet is immediately relayed further after detecting the target address in Store and Forward a data packet is first read in completely and chec...

Page 16: ...rnet Switch User s Manual Kyland Telecom 8 auto sensing enforced full half duplex enforced 10M 100M etc Setting for Port Rate KIEN6000T is able to set the rate of all ports through management as any i...

Page 17: ...forwarding of data packet 2 Optical fiber transceiver module is used for optical fiber interface offering stable performance 3 Industrial power supply with overcurrent overvoltage and EMC protection...

Page 18: ...ated into the environment via the ribbed heat dissipation surface in the form of radiation and convection greatly increasing the high temperature resistance of equipment Discarding the traditional for...

Page 19: ...the unit It may get hot during working so never touch the shell when the equipment is working to avoid burning 3 2 2 Front panel The front panel of KIEN6000T industrial Ethernet switch has integrated...

Page 20: ...rt number of 4 and 8 and SC or FC connector Optical fiber interface should be used in pairs TX and RX are a pair TX interface is the transmitting end connected to the receiving end RX of the optical f...

Page 21: ...dicators on the front panel of KIEN6000T can indicate system operation and port status helping detect and eliminate faults Table 3 1 describes the meanings of all indication lamps on the front panel T...

Page 22: ...3 Top panel The top panel of KIEN6000T industrial Ethernet has integrates two power input terminals for redundant power supply alarming relay output terminal network management port DIP switch for swi...

Page 23: ...the two terminal locking screws to firmly connect the terminal with the power connector 24V Ter m i nal Locki ng S cr ew s Locki ng S cr ew s f or P ow er C abl es P ow er G r ound P r ot ect i on G r...

Page 24: ...g and another end DB9F plug to connect the network management interface of KIEN6000T with the 9 pin serial port of the control computer Operating the local management software provided by KYLAND Telec...

Page 25: ...et to redundant mode F is used for setting the equipment to local or remote attribute when the optical fiber interface is in redundant mode If T is in OFF when F shifts to ON the equipment is set as l...

Page 26: ...l and others as remote 3 2 4 Bottom panel There is a threaded hole for grounding in the bottom panel of KIEN6000T M3 8 screw and 3 cold pressed terminal for grounding free of charge will be delivered...

Page 27: ...Kyland Telecom Chapter 3 Hardware Structure 19 Figure 3 8 Grounding method for KIEN6000T case...

Page 28: ......

Page 29: ...rature 35 75 relative humidity 10 95 non condensable 3 Grounding resistance requirement 5 4 Check whether optical fiber cable is laid properly and whether proper optical fiber connectors are used acco...

Page 30: ...T DC18 36V 6VA KIEN6000T 2M E6T2M050068 http www kyland com cn Made In China Invisible laser radiation Do not stare into beam or view directly with optical instruments CAUTION The casing is part of th...

Page 31: ...g is part of the heat sink design and may be hot to the touch Made In China http www kyland com cn INPUT DC18 36V 6VA E1A8T050068 S N Kyland Telecom KIEN1000 8T Model DIN Rail Spri ng a b Figure 4 2 M...

Page 32: ...head screwdriver to unscrew the two screws fastening the DIN rail connector socket on KIEN6000T equipment and remove the green DIN rail connector socket 2 Take out the wall mounting plate and the scre...

Page 33: ...lastic expansion bolts in the holes on the wall screw down the tapping screws into the plastic expansion bolts with a cross head screwdriver but do not screw down thoroughly reserve a distance of arou...

Page 34: ...properly mounting KIEN6000T it is ready for cable mounting and connection mainly including cable connection for the following interfaces 1 Service interface KIEN6000T provides 10Base T 100Base TX RJ45...

Page 35: ...laser meets class 1 laser product requirements and harmless to eyes under normal operation However when the equipment is switched on do not stare directly into the optical fiber transmitting interface...

Page 36: ...equirements 1 Before cable wiring check whether the specifications models and quantities of all cables comply with the construction drawing design and contract requirements 2 Before cable wiring it is...

Page 37: ...r line and grounding conductor should be not folded or blended together If a cable line is overly long coil and place it in the middle of the cabling rack do not let it cover on other cables 9 When la...

Page 38: ......

Page 39: ...ort of the two testing computers by straight through network cable transmit Ping command mutually both sides can correctly Ping to each other and no data package is lost At the same time the yellow la...

Page 40: ...N 6000T Figure 5 2 Optical port testing Example of PING command The IP address of testing computer 1 is 192 168 100 10 and that of the testing computer 2 is 192 168 100 11 operating command in the Ope...

Page 41: ...ndancy optical fiber interface an optical fiber redundant ring network can be formed The recovery time of the ring network redundancy is less than 300ms when the system is in fault It is widely applie...

Page 42: ...6 1 Optical fiber redundant ring network composed by KIEN6000T Attention When KIEN6000T is forming a redundant ring network connection of optical port 4 and 8 are recommended namely the optical port 4...

Page 43: ...d configuration The optical port may be order made single mode multi mode The power supply voltage is DC 25V the specific configuration and its corresponding models are shown as Table 6 1 Table 6 1 Co...

Page 44: ......

Page 45: ...the inserting direction is correct 1 8 8 1 Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded twisted pair STP will be used for the connectio...

Page 46: ...DI X signal name MDI signal name 1 Receiving data RD Output data TD 2 Receiving data RD Output data TD 3 Output data TD Receiving data RD 6 Output data TD Receiving data RD 4 5 7 8 Unused Unused Note...

Page 47: ...Cable type and specifications Cable Type Max length Connector 10Base T Cat 3 4 and 5 100 ohm UTP 100m 328 foot RJ 45 100Base TX Cat 5 100 ohm UTP 100m 328 foot RJ 45 100Base FX 50 125 or 62 5 125 m co...

Page 48: ......

Page 49: ...ng and network configuration function Traffic Control It is a congestion control mechanism The network equipment sends the data to the equipment which has overloaded and causes the port to congest The...

Page 50: ...Technology CO LTD Address 5 F Office Building Transport Center East of Xisanqi Bridge Haidian District Beijing China Website http www kyland com cn Postcode 100096 Tel 86 10 82900770 Fax 86 10 8290078...

Reviews: