Page 1: ...SICOM3000 Industrial Ethernet Switch Hardware Installation Manual Publication Data Jun 2013 Version V1 0 No 1 12 02 0 ...

Page 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2013 Kyland Technology Co Ltd ...

Page 3: ...se keep the device clean if necessary wipe it with a soft cotton cloth Do not place any irrelevant materials on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed metal wires because they may be oxidized or electrified Install the device in accordance with rel...

Page 4: ... If any part is lost contact our sales or technical support personnel to purchase the substitute Do not purchase parts from other channels Dispose of the device in accordance with relevant national provisions preventing environmental pollution In the following cases please immediately shut down your power supply and contact your Kyland represen tative Water gets into the equipment Equipment damage...

Page 5: ...ĂĂĂĂĂĂĂĂĂ 12 4 2 100Base FX Ethernet PortĂĂĂĂĂĂĂĂĂĂĂĂĂĂ 14 4 3 1000Base X 10 100 1000Base T X SFP SlotĂĂĂĂĂ 15 4 3 1 Gigabit SFP Optical ModuleĂĂĂĂĂĂĂĂĂĂĂ16 4 3 2 Gigabit SFP Electrical ModuleĂĂĂĂĂĂĂĂĂĂ 18 4 4 Console PortĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂ 19 4 5 GroundingĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂ20 4 6 Power Terminal BlockĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂ21 4 7 Alarm Terminal BlockĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂ24 5 LEDsĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂĂ2...

Page 6: ......

Page 7: ... power input and sound EMC protection of RJ45 ports The redundant network and power input support guarantees the reliable operation of the system SICOM3000 provides powerful network management functions The device can be managed through CLI Telnet Web SNMP based and OPC network management software The series switches support DIN rail and panel mounting SICOM3000 provides up to two 1000Base X 10 10...

Page 8: ...Panel of SICOM3000 2GX 2S M 6T 2 1 Front Panel 1 2 3 4 8 5 G2 G1 Speed Link ACT 7 6 3 8 7 6 5 4 2 1 9 10 11 ƽ Front Panel of SICOM3000 2GX 2S M 6T Caution It is recommended to purchase the port dustproof shield optional to keep ports clean and ensure switch performance ...

Page 9: ...LED 6 G1 Gigabit SFP slot G1 and its connection status LED 7 7 100Base FX Ethernet port 7 and its connection status LED 8 8 100Base FX Ethernet port 8 and its connection status LED 9 1 6 Six 10 100Base T X Ethernet ports 10 Speed 10 100Base T X Ethernet port speed LED yellow 11 Link ACT 10 100Base T X Ethernet port connection status LED green Note The appearance of SICOM3000 MA C 2GX 2S M 6T is id...

Page 10: ...Structure and Interface 4 Figure 2 Front Panel of SICOM3000 2GX 8T 1 2 3 4 8 5 G2 G1 Speed Link ACT 7 6 3 8 7 6 5 4 2 1 9 ƽ Front Panel of SICOM3000 2GX 8T ...

Page 11: ...D 2 PWR2 Power 2 LED 3 Run Running LED 4 Alarm Alarm LED 5 G2 Gigabit SFP slot G2 and its connection status LED 6 G1 Gigabit SFP slot G1 and its connection status LED 7 1 8 Eight 10 100Base T X Ethernet ports 8 Speed 10 100Base T X Ethernet port speed LED yellow 9 Link ACT 10 100Base T X Ethernet port connection status LED green ...

Page 12: ...nel Table 4 Description of the Top Panel 2 2 Top Panel PWR1 PWR2 L N N L FAULT Console 1 2 3 4 FAULT L N N L PWR1 PWR2 No Identifier Description 1 Power terminal block 2 Alarm terminal block 3 Console Console port w e r c s g n i d n u o r G 4 ...

Page 13: ... Dimension Drawing 70 123 56 4 6 5 75 140 178 195 123 75 75 6 35 140 Caution ƽ As part of the heat dissipation system the switch housing becomes hot during operation Please use caution when coming in contact and avoid covering the switch housing when the switch is running ƽ The figures in this manual are only for reference ...

Page 14: ...sunlight distant from heat source and areas with strong electromagnetic interference Step 1 Select the mounting position for the device and guarantee adequate space and heat dissipation dimensions 75mm 140mm 123mm Step 2 Insert the connecting seat onto the top of the DIN rail and push the bottom of the device inward and upward to ensure the DIN rail fits in the connecting seat Make sure the device...

Page 15: ...f the connecting seat as shown on the left of the following figure Step 2 Move the device in direction 2 until the bottom of the device is detached from the DIN rail Then move the device in direction 3 and uplift the device until the top of the connecting seat is detached from the DIN rail Figure 7 DIN Rail Dismounting ƽ DIN Rail Dismounting 1 2 3 Screwdriver DIN rail connecting seat DIN rail ...

Page 16: ...d heat dissipation dimensions 75mm 140mm 123mm Step 3 Punch four holes in the selected position according to the dimensions for panel mounting Insert four screws into the four holes respectively and turn the screws with a screwdriver until about a 5mm distance is left between each screw head and the wall Step 4 Align the four mounting holes on the plate for panel mounting with the four screws Inse...

Page 17: ...re in the Ф6 5 positions in the following figure Then remove the plate for panel mounting from the four screws to detach the device from the wall or inner wall of the cabinet Step 2 Loosen the screws completely with a screwdriver Remove them from the wall or inner wall of the cabinet Then remove the plate for panel mounting from the rear panel to complete dismounting the device ...

Page 18: ...ght through or cross over cable The following figure shows the pin numbers of the RJ45 port The following table lists the pin definitions of the 10 100Base T X RJ45 port 4 Connection 4 1 10 100Base T X Ethernet Port Figure 10 RJ45 Port Table 5 Pin Definitions of 10 100Base T X RJ45 Port ƽ Pin Definition Note and indicate level polarities Pin MDI X Signal MDI Signal 1 Receive Data RD Transmit Data ...

Page 19: ...tor Straight through cable Wiring sequence Cross over cable Wiring sequence RJ45 connector 8 1 1 2 3 6 1 2 3 6 1 2 3 6 3 6 1 2 Note The color of the cable for RJ45 connector meets the 568B standard 1 orange and white 2 orange 3 green and white 4 blue 5 blue and white 6 green 7 brown and white and 8 brown ...

Page 20: ...e is powered on Device A SC port Device B SC port SC SC cable Wiring sequence TX RX TX RX TX RX TX RX 100Base FX Ethernet port is equipped with FC ST SC connector and each port consists of TX transmit port and RX receive port To enable data transmission between Device A and Device B connect the TX port of Device A to the RX port of Device B and the RX port of Device A to the TX port of Device B Th...

Page 21: ...requires an SFP optical electrical module to enable data transmis sion The following table lists the gigabit SFP optical electrical modules optional supported by the series switches 4 3 1000Base X 10 100 1000Base T X SFP Slot Table 6 Gigabit SFP Optical Electrical Modules ...

Page 22: ...ce A and Device B connect the TX port of Device A to the RX port of Device B and the RX port of Device A to the TX port of Device B as shown in the following figure Figure 13 Gigabit SFP Optical Module Figure 14 Fiber Connection of an SFP Optical Module 4 3 1 Gigabit SFP Optical Module Device A LC port LC LC cable Device B LC port TX RX TX RX TX RX TX RX Wiring sequence ...

Page 23: ... LED is on the connection is correct If the LED is off the link is not connected This may be caused by incorrect connection of the TX and RX ports In this case swop the two connectors at one end of the fibers Optical fiber SFP optical module SFP slot The device uses laser to transmit signals in fibers The laser meets the requirements of level 1 laser products Routine operation is not harmful to yo...

Page 24: ... then insert the RJ45 connector of the twisted pair into the SFP module ƽ How to Connect the SFP Electrical Module Figure 16 Gigabit SFP Electrical Module Figure 17 Connecting the SFP Electrical Module 4 3 2 Gigabit SFP Electrical Module RJ45 connector SFP Electrical module SFP slot ...

Page 25: ...e Port ƽ DB9 RJ45 Console Cable Figure 18 Console Port Figure 19 Wiring Sequence of DB9 RJ45 Console Cable Facing the A direction Facing the B direction 9 6 8 1 5 1 A B DB9 connector RJ45 connector Wiring sequence 2 3 5 2 3 5 Console One end of a DB9 RJ45 console cable is crimped RJ45 connector to be inserted into the console port of the switch and the other end is the DB9 connector to be inserted...

Page 26: ...rounding protects the switch from lightning and interference There fore you must ground the switch properly You need to ground the switch before it is powered on and disconnect the grounding cable after the switch is powered off The switch provides a grounding screw on the top panel for chassis grounding After crimping one end of the grounding cable to a cold pressed terminal secure the end to the...

Page 27: ... terminal block When the redundant power supply is used and one power input is faulty the device can continue operating properly thereby improving network reliability The following figure shows the 5 pin 5 08mm spacing plug in terminal block ƽ 5 Pin 5 08mm Spacing Plug in Terminal Block Figure 21 5 Pin 5 08mm Spacing Plug in Terminal Block socket PWR1 PWR2 L N N L 1 2 3 4 5 Note 0 75mm2 Cross sect...

Page 28: ...ep 4 Insert the terminal block with the connected wires into the terminal block socket on the device Step 5 Connect the other end of the power wires to the external power supply system according to the power supply requirements of the device View the status of the power LEDs on the front panel If the LEDs are on the power is connected properly ƽ Wiring and Mounting No Signal DC Definition AC Defin...

Page 29: ...t the power input meets the power requirement If connected to an incorrect power input the device may be damaged Warning ƽ Do not touch any exposed conducting wire terminal or component with a voltage warning sign because it may cause damage to humans ƽ Do not remove any part or plug in or out any connector when the device is powered on Figure 22 Connection of 5 Pin 5 08mm Spacing Plug in Terminal...

Page 30: ...following models are used for alarm output When the models work properly the normally open contacts of the alarm relay are closed and the normally closed contacts are open when an alarm occurs the normally open contacts are open and the normally closed contacts are closed ƽ Alarm Output 4 7 Alarm Terminal Block The device provides a 3 pin 5 08mm spacing plug in terminal block for alarm output or i...

Page 31: ...e alarm terminal block are redefined as listed in the following table The switch receives external alarm signals from the terminal block and outputs corresponding alarms ƽ Alarm Input Step 1 Remove the alarm terminal block from the switch Step 2 Secure the three wires for alarm into the alarm terminal block in the required sequence Step 3 Insert the alarm terminal block into its socket ƽ Wiring an...

Page 32: ...LEDs 26 5 LEDs Table 11 Front Panel LEDs Speed yellow Connection status green ...

Page 33: ...ng a Connection Step 1 Connect the console port of the switch to the 9 pin serial port of a PC with the delivered DB9 RJ45 console cable Step 2 Open Hyper Terminal in Windows OS On the computer s desktop click Start All Programs Accessories Communications Hyper Terminal Step 3 Create a connection Switch as shown in the following figure ...

Page 34: ...nication port in use as shown in the following figure Figure 25 Selecting a Serial Port Note To confirm the communication port in use right click My Computer and select Property Click Hardware Device Manager Port to view the communication port ...

Page 35: ...Then the following commands can be used to perform operations Figure 26 Setting Port Parameters Table 12 CLI Commands Step 5 Set port parameters Bits per second 115200 Data bits 8 Parity None Stop bits 1 and Flow control None as shown in the following figure ...

Page 36: ...hen you can run the commands in Table 12 to perform operations Figure 27 Access through Telnet Note ƽ IE8 0 or a later version is recommended ƽ For details about how to access the switch and other operations refer to the Web operation manual in the delivered CD Step 1 Connect the network port of a PC to the Ethernet port of the switch with a network cable Step 2 On the Windows desktop click Start ...

Page 37: ...Basic Features and Specifications 31 7 Basic Features and Specifications ...

Page 38: ......