14.1 Introduction of ALARM management module
SICOM series switches support device alarm and related alarm report (SNMP trap), alarm
enable/disable, and alarm searching. It assures that the alarm will be reported to the
customer timely and accurately.
SICOM series switches support following alarm type:
Alarm type
Meaning
Link down alarm
Alarm while the link is down
DT-Ring master ring open alarm
Alarm while the master’s ring status is open
Power supply alarm
Alarm while any of the working dual power
supplies power is low level
IP conflict
Support monitoring IP address conflict
MAC conflict
Support monitoring MAC address conflict
Note: If IP conflict and MAC conflict happen together, it means these are own testing packets
and it will not alarm.
SICOM series switches support alarm trap. While alarm is enabled, and alarm occurs, it will
send SNMP trap to the manager to report the alarm.
SICOM series switches support alarm search by web page search, CLI/Telnet search, and
SNMP management software search.
SICOM series switches support LED display for working status. While the device is working
properly, the LED will flash in a frequency of 0.5HZ.
14.2 ALARM configuration
14.2.1 Port link down enable/disable
Port link down alarm enable/disable can be set through CLI command. The port disabled for
link down alarm will not send trap message to the manager.
Setting port alarm management status
KYLAND(config)#alarm port-id <1-26> alarmtype 8001 adstate
<1-2>
The parameter <1-26>: Port index.
8001 is alarm type.
The parameter <1-2>: 1 for Enable and 2 for Disable.