Chapter 6 - SAT Measuring Range
51
106 V3.2
6.4.7.2
Script structure
Sample of a DiSEqC-Script:
WideBand mode UAS 474 2 x 950..3000 MHz
E2 7F FB 40 00 00 03 52 00 00 03 52; LOF 9,75 GHz, IF 950..3000 MHz
E2 7F FB FE; store data
// comment
First line: Comment, which is shown during the whole processing.
Further lines: DiSEqC-commands composed of hexadecimal figures and a blank between each 2
bytes. A command have to start in the first column of a line and is terminated by a semicolon. The
rest of the line is treated as a comment.
A double backslash // marks a comment.
An exception is the „18V“ codeword, which must be written in an own line. Thereby the LNB-
voltage is set to 18V to be confort for an UNICABLE standard transmission. Otherwise the LNB-
Voltage is set to 14V