background image

7

8

6.User Code

6-1  The preset User Code is 1234. Please delete it and create your personal code
       before using lockset for the first time.
6-2  Up to 6 sets of User codes can be saved.
6-3  User Code is only for activating the lock, without programming function.
6-4  User Code is 4-10 digits in length.
6-5  User Code can be deleted or changed anytime if needed.

7.Delete Individual User Code

7-1  User Codes can be deleted individually. You can reset the same number as code
       after it has been deleted.
7-2  Programming code is required to delete individual User code.

8.Delete All User Codes At Once

8-1  All User Codes can be deleted at once. You can still reset the same numbers
       as codes after they have been deleted.
8-2  Auto-locking and Keypad locking function will be invalid after deleting all
       User Codes and the lock can only be operated by key. These functions will be
       restored when recreate new User Codes.
8-3  You need to enter Programming Code to delete all User Codes.

9.Temporarily Disable All User Codes

9-1  Auto-locking and Keypad locking function will be invalid when User Codes are
       temporarily disabled. The lock can only be operated by key during that time.
9-2  Repeat the programming steps again to restore the User Codes.

10.Create a Disposable User Code

10-1 Disposable User Code can be used only once.
10-2 You can reset the same number as Disposal User Code more than once.
10-3 Programming Code is required to create a Disposable User Code. 

11.Restore Preset Factory Code

11-1 You can restore Preset Factory Code by pressing “R” button on the interior
        receiver module when you forget Programming Code or you want to cancel all
        previous settings.
11-2 After restoring factory settings, the Programming Code will be 0000; the
        User Code will be 1234 again.

12.Unlock the door

The door can be unlocked by key or pressing User Code on keypad from outside or by
interior turn-piece.

13.Lock the door

The door can be locked by key or pressing Programming Button on keypad from
outside or by interior turn-piece.

14.Incomplete Door Closing / Opening

14-1

 

If the door cannot be closed completely either because of an obstruction or motor

        failure, you will see button 1 flash in red 3 times and hear 3 beeps
        (No alarm when it's in mute). You need to enter User Code to unlock the door for
        remaining the bolt retracted, and press Programming Button to lock the door
        again.
14-2 If the latch bolt gets stuck or can't extend/retract completely all the time, please
        check if the strike aligns with the latch bolt perfectly and adjust the strike to
        proper position if required. After long use of the door hinge, the latch bolt might
        get stuck easily because the door is deformed or lopsided.

15.To Activate / Deactivate Auto-Locking Function

15-1

 

The door will automatically lock itself within 10~99 seconds when this function

        is programmed.
15-2

 

This function is not preset at the beginning; it can be set if needed.

15-3

 

The preset delay-time is 30 seconds; you can adjust the period you want.

15-4

 

Please repeat the same programming steps to cancel Auto-Locking function

        when needed.
15-5

 

The system will alarm twice if

 

the latch bolt gets stuck or cannot extend/retract

        completely.

         

You need to enter a valid User Code to unlock the door and re-lock it.

        The auto-locking function will be restored then.

16.Toggle Mute On/Off

16-1 You will hear beep sounds when pressing keypad, programming or operating
        errors. It can be turned off if needed. 
16-2 LED Illumination is still functioning when it's in mute. As there will be no any
        warning alarm, we suggest not to mute the beeper if it's not necessary.   
16-3 Motor operating sound cannot be muted.

 

Summary of Contents for PL1

Page 1: ...e of purchase If you discover a defect in the Product covered by this warranty we will repair or replace the item at our option using new or refurbished components 2 Exclusions This warranty covers defects in manufacturing discovered while using the Products as recommended by the manufacturer rather than occurred by the act of God and damages caused by misuse abuse and unauthorized modification 3 ...

Page 2: ...t the strike and tighten it with screws Note please use tapping screws for a metal door 1 2 2 3 4 70mm a b c d a b c KEYPAD ELECTRONIC DEADBOLT INSTALLATION INSTRUCTIONS 1 Mark The Door With Template Select the height and backset as desired on the door face use the TEMPLATE as an indication to mark the center of the circle on the door face and the center of the door edge 2 Drill Holes Using the ma...

Page 3: ...e Face the door from outside the door is left handed if the hinge is on the left hand side of the door whereas the door is right handed if the hinge is on the right hand side of the door Interior Exterior Door Hinge Left Handed Right Handed 8 Adjusting Turn Piece Turn the turn piece to left for 45 degrees for a right handed door Turn the turn piece to right for 45 degrees for a left handed door Tu...

Page 4: ...eration 3 2 Button 1 flashes green twice with successful programming 3 3 Button 1 flashes red 3 times when there is an operation error 3 4 Button 1 flashes red 5 times when code is entered incorrectly the operation will stop for system protection Refer to 17 3 5 Button 1 flashes orange 3 times when system has been restored to default settings 3 6 Button 1 flashes orange slowly while in programming...

Page 5: ...ode will be 0000 the User Code will be 1234 again 12 Unlock the door The door can be unlocked by key or pressing User Code on keypad from outside or by interior turn piece 13 Lock the door The door can be locked by key or pressing Programming Button on keypad from outside or by interior turn piece 14 Incomplete Door Closing Opening 14 1 If the door cannot be closed completely either because of an ...

Page 6: ...rogramming Code PC 10 Function Programming Detect Left Right Hand Door Installation Enter PC 0 Remark Please run the door handing identifying process before initial setup or once default settings are restored Leave lock unlocked while programming Add New User Code USER Code UC Enter PC 1 Enter New UC Remark Up to 6 sets of User Code can be saved User Code should be 4 10 digits in length Delete An ...

Page 7: ...factory default settings and re execute door handing indentifying process Situation 4 Although succeeded in the first execution of the door handing indentifying process the latch does not work Feeling that the motor runs powerlessly the latch bolt is stuck and the turn piece inside cannot be rotated Causes Low battery Solutions Please replace with new batteries 11 Programming Code PC USER Code UC ...

Page 8: ...olt coming out when you press the programming button to lock the door however three short beeps are emitted Conversely while the door is open no beeps are emitted when locking the latch bolt Causes 1 The depth of the latch bolt hole is insufficient 2 The latch bolt is not aimed at the opening of the strike Solutions 1 Please dig the latch bolt hole deeper for the strike deeper min depth of 2 5 cm ...

Page 9: ...vert par cette garantie nous réparerons ou remplacerons le produit à notre discrétion en utilisant des composants neufs ou remis à neuf 2 Exclusions de garantie Cette garantie couvre les vices de fabrication découverts lors de l utilisation du produit tel que recommandé par le fabricant et non les dommages résultant d actes de Dieu d une utilisation incorrecte ou abusive ou encore de modifications...

Page 10: ...e de la porte 2 PERCEZ LES TROUS a Percez un trou de 2 1 8 po 54mm à travers la surface de la porte Assurez vous de percer des deux côtés pour éviter de laisser des éclats de bois b Percer un trou de 1 po 25 4mm pour le verrou reportez vous à l étape 4c pour un verrou à enfoncement 3 INSTALLEZ LE VERROU a b c d a Insérer le verrou dans le trou et ajustez en la position de manière à ce qu il soit p...

Page 11: ...uvent du côté gauche de la porte vue de l extérieur et que celle ci ouvre à gauche si les charnières se trouvent du côté droit de la porte vue de l extérieur vers la gauche Porte Intérieur Extérieur vers la droite Charnières 8 AJUSTEMENT DU TOURNIQUET Faites pivoter le tourniquet à 45 degrés vers la gauche si la porte ouvre vers la droite Faites pivoter le tourniquet à 45 degrés vers la droite si ...

Page 12: ...Le bouton 1 clignote en vert lorsqu une manipulation est effectuée avec succès 3 2 Le bouton 1 clignote en vert deux fois lorsqu une programmation de la serrure est effectuée avec succès 3 3 Le bouton 1 clignote en rouge trois fois lorsque survient une erreur de manipulation 3 4 Le bouton 1 clignote en rouge cinq fois lors de l entrée de codes incorrects La serrure se désactive alors pour protéger...

Page 13: ...nique ne sera plus valide après avoir été utilisé une seule fois 10 2 Vous pouvez utiliser le même code d usager à usage unique plusieurs fois Il devra être reprogrammé chaque fois 10 3 Vous devez d abord entrer le code de programmation pour créer un code d usager à usage unique 11 Réinitialisation à la configuration par défaut 11 1 Vous pouvez restaurer les codes prédéfinis par défaut en appuyant...

Page 14: ...ion de la serrure dans le noir 1 Nous recommandons d utiliser des piles alcalines afin de stabiliser l alimentation électrique du système 2 N utilisez qu un type de pile d une même marque et ne joignez pas des piles alcalines avec des piles zinc carbone ordinaires 3 N utilisez pas de produit chimique ni d huile avec additifs pour nettoyer la serrure ceci risquerait d endommager la surface de la se...

Page 15: ...Après l installation de la serrure et des piles la porte ne peut être verrouillée et trois bips courts sont émis lorsque vous appuyez sur le bouton de programmation Causes Le processus d identification de l orientation de la serrure n est pas encore terminée Solutions Veuillez exécuter le processus d identification de l orientation de la serrure dès que l installation de la serrure est terminée Si...

Page 16: ...t mais tout à coup le pêne se bloque et le tourniquet à l intérieur ne peut pas être mis en rotation même pas avec la clé Causes La détection de la position du loquet de verrouillage est anormale Solutions Rtirez une seule pile puis appuyez sur un bouton du panneau avant pour vider l alimentation électrique et retirer la pile suivante Le pêne redétecte automatiquement sa position par la suite Atte...