Control Panel Jumper Instructions

To be used in the event of a control failure.

1.  Remove the control panel from the bezel and disconnect the wire harness.

(See 

Figure 2

.)

2.  Make sure the area around and below the motorhome is clear of all obstructions

and that no personnel are under the vehicle.

3.  Plug the large connector of the jumper assembly into the wire harness (Figure 3.)

4.  Plug the 4-way connector into the wire harness. 

CAUTION: Pump will start

immediately and the jacks will begin to retract.

(See 

Figure 3.

)

5.  After jacks have been fully retracted, immediately disconnect the 4-way connector

on the jumper assembly from the wire harness to shut off the pump (

Figure 3.

)

Failure to immediately remove the 4-way connector can cause over-heating
of the pump motor and permanent damage to the system.

6.  Remove the large connector of the jumper assembly from the wire harness.

7.  Have jack system serviced at a qualified service center prior to using the jack

system.

Figure 2: Disconnect the wire
harness from the back of the
control panel.

Figure 3: Attach the Jumper Assembly to the Wire Harness.

NOTE: Immediately disconnect the 4-way connector after the jacks are fully
retracted.  Failure to immediately remove the 4-way connector can cause
over-heating of the pump motor and permanent damage to the system.

4-WAY

CONNECTOR

JUMPER

ASSEMBLY

WIRE

HARNESS

CONTROL

PANEL

WIRE

HARNESS

Summary of Contents for level best 2000

Page 1: ...ervice Department at 1 800 736 9961 WARNINGS Do not use the Level Best system as a lift for changing tires or working under the vehicle Never check for hydraulic fluid leaks using your hands and or an...

Page 2: ...ssible this will minimize the extent of leveling 2 Check that the area under the vehicle is free from any obstacles that might interfere with the operation of the levelers Check the ground surface to...

Page 3: ...ted The LED will illuminate in manual version only The four UP DOWN switches control the leveling jacks independently Pushing these switches operates the corresponding jack causing it to retract UP or...

Page 4: ...cks Locate the ON OFF button on the upper left of the control panel Momentarily depress this switch to activate the leveling system The LED will light up and be a steady green indicating that the syst...

Page 5: ...Replace and or repair as needed Verify that all mounting bolts have been tightened to 80ft lbs Care and Maintenance Turn on the coach ignition and press the ON OFF button on the control The two top i...

Page 6: ...is stuck tap solenoid to unstick it or replace the solenoid 6 To retract jacks with a control failure see Control Panel Jumper Instructions on Page 7 This list represents a cross section of some possi...

Page 7: ...nect the 4 way connector on the jumper assembly from the wire harness to shut off the pump Figure 3 Failure to immediately remove the 4 way connector can cause over heating of the pump motor and perma...

Page 8: ...air inadequate maintenance or deterioration due to normal wear This warranty does not apply to electrical wiring or hydraulic hoses The purchaser shall pay all shipping or other transportation charges...

Reviews: