To stabilize the vehicle once it has been leveled, any unused leveler must be extended into
firm contact with the ground. Accomplish this by using the appropriate individual leg leveling
switch so as not to affect the level of the coach.
CAUTION: Overextending the levelers during stabilizing will cause the vehicle to
become unlevel and result in a loss of stability. If a leveler has been overextended,
press the ‘up’ portion of the respective switch until the vehicle lowers into the level
plane again. Do not attempt to use the other levelers to raise the vehicle to a higher
level plane.
Control Panel Functions
Manual Leveling
The ON/OFF switch, located in the upper left hand corner, controls the supply of power for all
panel functions, activation of this switch is indicated by its green LED.
The ALL UP (leg retract) switch is located in the lower left hand corner of the control panel.
Activation of this switch causes all legs to retract to the travel position. When the retract
sequence is completed the ALL UP LED will turn green to indicate that it is now safe to move
the motor home.
The diamond shaped BI-LEVEL switch, located in the center of the panel, activates the
extension of the leveling jacks in pairs. Use of this switch greatly simplifies the leveling
process and significantly reduces the amount of stress created by the leveling process on the
motor home. Operation of this switch illuminates the yellow LED’s corresponding to the jacks
that are being activated. The LED will illuminate in manual version only.
The four UP/DOWN switches control the leveling jacks independently. Pushing these
switches operates the corresponding jack causing it to retract (UP) or extend (DN). Operation
of this switch lights the yellow LED corresponding with the jack activated. The LED will
illuminate in manual version only.
Level Best Operation Guide
Page 3
SEMI-AUTOMATIC FUNCTION
When an AUTO MODE sensor is connected to
a manual control, the jack indicator lights act as an indicator of the level
condition of the coach. A light that is ‘on’ indicates the high corner of the
coach. Push the BI-LEVEL pair button corresponding to the end of the coach
you would like to raise. When the light comes ‘on’, stop the action of that
button. In this way the jack indicator lights act as a bubble-level, indicating
the level condition of the coach.
FULLY-AUTOMATIC FUNCTION
Coaches equipped with AUTO MODE
can be operated the same as manual or semi-automatic versions. The fully-
automatic unit functions the same until the AUTO MODE switch is pressed.
Pushing the AUTO MODE switch causes the system to extend a pair of jack legs
to the ground. Next the other pair of legs is extended to the ground and the system
begins the auto level sequence. During the auto level sequence the system will run
one to three of the jacks depending on the level condition of the coach. On completion,
the system will check the level condition of the coach and either re-run the sequence
or display a green LED light under the AUTO MODE button to indicate that the
sequence is complete. Typical coach level capability is 0.3 degrees from side to
side and front to rear.