8 -
FAULT DIAGNOSIS
8.1 -
POSSIBLE FAULTS
C
AUSE
R
EMEDY
Traction is not correctly
performer.
It lacks oil [see para. 7.3.1].
Unscrewing is not correctly
performed.
When inserting the rivet nut in the tie rod, after pressing the trigger (A), unscrewing is not
correctly performed.
Oil is not enough: add some.
Unscrew without traction.
O-ring (
B
) broken: replace it.
Slows the unscrewing after
traction.
Working intensively it loses greasing and tends to harden.
Remove the piston (
G
), and grease.
Replacing parts of the manostat.
When you have to work on the manostat:
1.
Remove air
2.
Loosen the oil cap (
27
) to avoid the coming out of gasket (
C
). In case of replacement use guide
(
1
), insert the gasket (
2
) and push it with the pin (
3
). If after reassembling of all parts of the
pressure switch, it does not work properly, o-rings (
O1
,
O2
,
O3
) have not been correctly
assembled:
O-ring (
O2
), when broken unscrews without making traction
O-ring (
O3
) makes traction but no unscrew
O-ring (
O1
) can leak air
Consequently it is advisable to replace all 3 o-rings(ORM 15x1) of the kit (ref.
41
).
S
O-ring
A
B
O-ring
B
G
C
1
2
3
O3
O2
O1