www.KVS-Klimatechnik.de
E-5
English
4
3 Scope of supply
3.1 Basic Device
The heat pump is of compact design and is supplied complete
with the components listed below.
The refrigerant circuit contains the Kyoto protocol approved re-
frigerant R404A with a GWP value of 3260. It is CFC-free, does
not deplete ozone and is non-flammable.
1)
Ventilator
2)
Evaporator
3)
Defrost end pressure switch
4)
Switch Box
5)
Filter dryer
6)
Compressor
7)
Liquefier
3.2 Switch Box
The switch box is located in the heat pump. It can be swung out
after removing the lower front cover and loosening the fastening
screw located in the upper right-hand corner.
The switch box contains the supply connection terminals as well
the power contactors, the soft starter unit and heat pump control.
The heat pump control is an electronic module, which controls
and monitors the complete swimming pool heat pump.
The swimming pool heat pump is operated via the remote control
provided.
4 Transport
ATTENTION!
When transporting the heat pump, ensure that it is not tilted more than
45° (in any direction).
Use a wooden pallet for transporting the heat pump to the final in-
stallation location. The basic device can be transported with a lift
truck, hand truck or by means of 3/4" pipes fed through the holes
in the base plate or frame.
ATTENTION!
The heat pump and transport pallet are only joined by the packing film.
Before using the transport holes in the frame, it is necessary to
remove the lower side panel assemblies. This is done by loosen-
ing each of the two screws at the base and then withdrawing the
panels by unhooking them from above. Rehang the panels by
gently pushing them in an upwards direction.
Be careful not to damage any components when inserting the
pipes through the frame.
Opening the cover
Closing the cover