FRU
Part Number
RF Cable
32-0566-0100
PC Cable
32-0628-06
CPU Fuse
16-0017-4000
The Antenna Unit printed circuit boards, Antenna LNB, elevation
stepping motor, and elevation drive belt may be removed and
replaced on site using common hand tools. Other TracVision 6
service must be done by your authorized dealer/installer,
distributor or by KVH. Evidence of tampering or unauthorized
repairs will void the warranty. The following are step-by-step
procedures for removing and replacing those components that
may be serviced.
Figure 4-1 depicts the location of a number of components within
the TracVision 6 Antenna Unit.
4-3
Maintenance
54-0166 Rev. B
U.S./Galaxy-style
LNB
European LNB
Elevation Motor
and Drive Assembly
Azimuth Motor
Antenna Gyro
PCB Cover
and PCBs
Figure 4-1
TracVision 6 Antenna Unit
(Baseplate Cut Away)
Table 4-1 (continued)
TracVision 6 Field
Replaceable Units
To help us continually improve the
quality and reliability of our
systems, please return any failed
component to KVH or KVH Europe
after you receive your replacement
part.