Technical Specification [Spectrum 20]
KVANT Spectrum 20 – full colour, OPSL & semiconductor diode laser system
Total Optical Power (installed): 20W
Total Optical Power (guaranteed): 20W*
Maximum Output Power: 21.6W
Colour Wavelength Output
Red
637nm
6000mW
Green
520nm
8000mW
Blue
445nm
6000mW
NOHD (Nominal Ocular Hazard Distance): 996m
Beam diameter at laser aperture: 5.5 × 5.5mm
Beam divergence: <1mrad (full angle)
Modulation: 0-5V analog, up to 50kHz
Module cooling: TEC
Scanning System:
Cambridge Technology CT6215 | 30kpps@8°, max. scanning angle 60° on both axes
Saturn 5, 50kpps@7°, max. scanning angle 60° on both axes (optional)
Control signal: ILDA, Ethernet, ArtNet and SD Auto
Power requirements: 100-240V/50Hz (±5%)
Consumption: 550VA/100-240V
Operation temperature: 10-40°C
Ingress protection rating: IP65
Dimensions (WxDxH): 465 × 260 × 391mm
Weight: 36kg
Laser safety features: Keyed interlock, emission delay, magnetic interlock, scan-fail safety, V-RAD 506
mechanical shutter | reaction time <20ms, adjustable aperture masking plate.
This laser system fully complies with the latest EN 60825-1, FDA regulations and TUV Laser Safety.
Kvant spol. s.r.o.
Spectrum series - v16816
Page 33 of 38