Switching ON sequence and User Interlock
1. Connect the system as showed on
Connection Diagram
.
2. Turn both E-STOP Remote and laser system safety keys to ON position.
3. Release the E-STOP button by pulling it upwards.
4. Open the aperture window by loosening the two bolts at the bottom of the aperture, adjust the
masking plate to desired position and tighten the bolts to secure it.
5. Press the Main Power switch located at the back panel.
6. Press the RESTART button on the E-STOP Remote.
What happens next?
1. The laser system starts up and performs a self-check during which you may hear the initial spin of
the cooling fans.
2. ScanFail safety indicator starts flashing and flashes for 60 seconds which indicates the Emission
Delay period.
3. The Interlock indicator stays switched off if the Interlock Connector or the E-STOP Remote are
connected correctly.
4. After 60 second Emission Delay period the laser system is ready to start output laser radiation.
Interlock Enabled, Laser Output Terminated
The Interlock is latched enabled and the laser projector’s beam output will be terminated if any of the
following events happen:
1. Power loss lasting greater than 2 seconds.
2. Mushroom emergency switch depressed.
3. #2 Key Switch on E-STOP Remote turned to OFF position.
4. #1 Key Switch on laser projector turned to OFF position.
5. Any other interruption to line No.1 of the cable leading to the E-STOP Remote.This includes any
user interlocks connected in series in the line No. 1 of this cable. Refer to Connection Drawing
below.
.
.
Please make sure that all laser display safety requirements are fulfilled in accordance
with laws of the country where this KVANT laser system is being used before switching
the system ON.
!
Kvant spol. s.r.o.
Spectrum series - v16816