21
i
28
EN
5.1
architect beam alignment
!
Although KVANT uses the latest
technology to protect all the critical
components inside this laser system
against Electrostatic Discharge, the
semiconductor laser diodes within
this system are extremely vulnerable
to it. This is due to some of the
electronic components being exposed
when the top cover is taken off.
If you decide to proceed with the
Beam Alignment process yourself,
it is absolutely essential that all the
common ESD protection rules are
strictly followed. We don’t accept
any responsibility for Electrostatic
Discharge damages to laser diodes
caused by customer.
1. Release and open 10pcs top cover fast access
fasteners.
2. Slowly remove the cover –
detach the GND wire
that
is attached to the top cover from the inside of the
system! To detach the wire gently pull it out from the
connector.
3. Removal of the cover will show the two internal
microswitch interlocks. Depress both microswitches to
operate the system in service mode.
4. Set small brightness of one of three colour channels
you want to align (either R, G or B) on your DMX
or remote controller. Keep other two colour channels
at zero level (other two colours have no output).
5. Power up the system as normal.
6. Determinate the misaligned laser diode’ beam
position among all diodes. It is easy to find it by hiding
individual diode beam with not reflective and not
flammable metal object.
7. Set the position of reflection mirror’s mount that
reflects misaligned laser beam with metric hex key
#1,5mm according following picture.
8. After the setting is done, service technician must
verify the functionality of both interlock microswitches
and close the top cover of Architect laser system.