background image

SVS 12EX LIFT

INSTALLATION INSTRUCTIONS

(110V)

SVS, INC.

    

Lifting Your Image

2513 Jenks Ave
Panama City, FL 32405
www.svslifts.com

Tel: 850-522-4747
Fax:850-522-4739
[email protected]

Western Sales
Tel: 720-283-6410
Fax:720-283-6424

SVS 12EX Lift Installation Instructions

Page 1 of 16 

Summary of Contents for 12EX LIFT

Page 1: ...S 110V SVS INC Lifting Your Image 2513 Jenks Ave Panama City FL 32405 www svslifts com Tel 850 522 4747 Fax 850 522 4739 sales svslifts com Western Sales Tel 720 283 6410 Fax 720 283 6424 SVS 12EX Lift Installation Instructions Page 1 of 16 ...

Page 2: ...ift Supporting Structure 7 7 Lift Installation 8 8 Electrical Connections 9 a How to Use the Wall Plate Controller 10 b Connecting to a Touch Screen Controller External Controller 11 9 Accessory Installation 11 10 Mounting the Projector 11 11 Cable Management 12 12 Setting the Show Position 13 13 Maintenance and Adjustments 14 14 Troubleshooting 15 SVS 12EX Lift Installation Instructions Page 2 of...

Page 3: ...d above the ceiling when not in use Show Projector automatically positioned for show operation Service Projector easily lowered for service Lift Capacity Up to 700 lbs 317 5 Kg Lift Weight From 410 lbs 186kg Maximum Projector Width 32 5 82 5cm Voltage Material 110V 60Hz 1 5Amps Steel Aluminum Nylon 220V 50Hz 75Amps Steel Aluminum Nylon Low Voltage Control Wall Plate Controller supplied with lift 2...

Page 4: ...Floor Access Motor Control Accessory 15 12 Volt Trigger A 1 year parts and 90 day factory labor warranty applies to the following SVS products All Lift Motors Accessory 1 Ceiling Closure FP1 Closure Panel Accessory 2 Plenum Shroud Accessory 9 Projector Mount Accessory 10 Dual Stack Projector Mount Accessory 13 Platforms A Return Material Authorization RMA number must be received from SVS prior to ...

Page 5: ...t s path If the bottom frame is lowered onto an obstruction the cable will slack and spill over the cable drum 4 PRELIMINARY INSTALLATION CHECKS SVS recommends that the Lift support structure holds at least four 4 times the weight of the Lift and projector combined Always follow your local building codes Required space for the Lift Projector and accessories should be considered prior to installati...

Page 6: ...the center of the projector and thus the center of the Lift 6 LIFT SUPPORTING STRUCTURE The SVS 12EX Lift should be mounted from six 1 2 rods The mounting hole locations are marked with a M in Figure 3 The thread rods must be supported by a rigid structure If the threaded rods exceed more than 2 feet 0 6 M from the support structure to the lift s top mounting holes cross bracing should be installe...

Page 7: ...re 6 Recommended Lift Support Structure for Flat Ceilings This allows for front to back and side to side adjustments of the Lift for alignment to the screen SVS 12EX Lift Installation Instructions Page 7 of 16 Figure 4 Cross Bracing Correct Height Figure 5a Recommended Lift Support Structure for Flat Ceilings ...

Page 8: ...hannel along with a locking washer and nut below the channel to lock into place IMPORTANT If you are installing an Accessory 2 Plenum Shroud with the Lift please read the Accessory Installation Instructions before beginning your installation The Lift support structure will need to allow enough space for the Plenum Shroud mounting hardware 7 LIFT INSTALLATION a Preparation 1 The Lift is shipped in ...

Page 9: ...blocks Remove the blocks by removing the screws and tie raps holding them in place TO AVOID CABLE SPILLS Do not push the lift bottom frame upwards once the Lift has been installed Make sure that there are no obstructions in the Lifts path If the bottom frame is lowered onto an obstruction the cable will slack and spill over the cable drum If the cable spills over the cable drum and the Lift is not...

Page 10: ...ssed The Lift will rise as long as you hold the toggle switch up The Lift can be raised with the key switch in either the Show or Service positions 4 The Off position on the key switch disables the Lift 5 The Power light only comes on when the Lift is raising or lowering Lift motor turning not when power is applied to the Lift Important The toggles switch on the Wall Plate Controller must be press...

Page 11: ...ccessory 2 Plenum Shroud require that hardware be added to the threaded rods supporting the Lift before the Lift is installed The Accessory 1 Ceiling Closure and FP1 Closure Panel attach the ceiling closure support brackets on the platform of the Lift using supplied threaded rods 10 MOUNTING THE PROJECTOR After checking the Lift operation and all clearances you can install the projector on the Lif...

Page 12: ...ccessory 7 Cable Retractor are standard equipment on all SVS 12EX Series Lifts The Cable Retractors are a spring loaded reel on the rear of the Lift The retractor automatically retracts your cable as the Lift ascends and releases your cable as the Lift descends Warning Over winding the reel or winding the reel counter clockwise will damage the cable reel springs Broken cable reel springs are not b...

Page 13: ...he large roller washer compresses the Show position switch when the Lift reaches the Show position 1 Place the key switch in the Service position and lower the Lift to the desired Show Position 2 Loosen the thumb screw holding the Show microswitch bracket in place and slide the Show microswitch bracket along the Lift frame until the large roller washer compresses the microswitch You should hear a ...

Page 14: ...arm stays in its down position If the solenoid does not pull up the microswitch will not allow the motor to turn when to lowering the Lift Check the Drum Lock pawl white nylon piece located on the Cable Drum The pawl should move freely and drop when when it reaches the top of the Cable Drum s rotation avoiding contact with the Drum Lock arm If the drum rotates too fast the pawl will swing out and ...

Page 15: ...lack wires the voltage should be about 24VAC if not contact SVS The Drum Lock Solenoid does not energize when you press the toggle switch down Note The Drum Lock Arm being down will cause the Drum Lock microswitch to disable the Lift motor Disconnect one of the solenoid wires and measure the resistance across the solenoid terminals If the resistance is less than 9 5 ohms replace the solenoid The D...

Page 16: ... Wallplate Controller to the up limit microswitch Lift stopped working after being connected to an external controller External controllers can not be used with Accessory 4 Power Sensor Accessory 5 Power Sensor with Screen Control or Accessory 15 12Volt Trigger Contact SVS to disable Power Sensor or 12Volt Trigger Wall Plate Controller key switch in the wrong position Place key switch in the Show ...

Reviews: