14
i
28
EN
Optionally to next Kvant Laset Projector
(E-Stop IN connector)
Cable to Kvant E-Stop box
Cable between Kvant Laser Projectors
(optional)
Cable between Kvant Laser Projectors
(optional)
User E-Stop Switch
(showed in OPEN state)
Theory of operation:
"Kvant Laser projetor" is supplied with "Kvant E-Stop Box"
and "Remote Interlock Bypass" including one cable.
If user doesn't need aditional "User E-Stop Switch",
"Remote Interlock Bypass" should be insterted into
"Remote Interlock Connector" on "Kvant E-Stop Box".
If user would like to use aditional "User E-Stop Switch",
"Remote Interlock Bypass" should be removed from
"User E-Stop Connector" on "Kvant E-Stop Box".
If "User E-Stop switch" is connected to "Kvant E-Stop Box"
and is in OPEN state, all "Kvant Laser projetors"
connected to "Kvant E-Stop Box" are disabled.
In this case NO EMISSION is possible.
If "User E-Stop switch" is connected to "Kvant E-Stop Box"
and is in CLOSED state and "Start Button" on
"Kvant E-Stop Box" was pressed, all "Kvant Laser projetors"
connected to "Kvant E-Stop Box" are enabled.
In this case EMISSION is possible.
Start Button
E-Stop
(Mushroom Switch)
Key
A
B
C
D
1
2
3
4
5
6
A
B
C
D
1
2
3
4
5
6
Author: Ing. STEFAN KUBANKA
KVANT Ltd.
E-Stop IN Connector
1
2
3
(XLR Male)
E-Stop OUT Connector
(XLR Female)
Kvant Laser Projector 1
E-Stop IN Connector
1
2
3
(XLR Male)
E-Stop IN Connector
(XLR Female)
Kvant Laser Projector 2 (optional)
1
2
3
1
2
3
Kvant E-Stop Box
1
2
3
1
2
3
E-Stop OUT Connector
(XLR Female)
Remote Interlock Connector
(XLR Male)
!
The E-STOP Remote is an integral
part of the laser projector. It is there
for the safety of the public as well
as the operator. Modifying or using
anything other than the E-STOP
Remote provided, in the manner it was
intended, may invalidate your KVANT
laser system’s variance.
E-STOP Connection Drawing including User
Interlock option