Initial Powering Operations for the ON-HD Lift
KVAL ON-HD Operation Manual
2-5
About Emergency Shutdown and Recovery
Important:
Learn all safety precautionary controls on the machine.
Depending on the model of machine, there are emergency shutdown (E-
Stop) switches located at key points around the machine.
The E-Stop switches are to be used when the machine is out of control
or is about to damage personnel or equipment.
When an E-Stop switch is activated, high voltage power is cut to the
machine. The motors will stop, but power to the PLC and the Operator
Station Screen will remain on.
To Resume Normal Operation after an E-Stop
If an E-Stop is activated, use the following procedure to recover, after the cause of the emergency
stop is resolved:
1.
De-activate the E-Stop switch by pulling it out.
2.
Push the
Start Machine
button on the operator's station
3. Home
the machine.
Other Safety Controls
Other safety controls can include:
•
Gate Latches:
Sensors are located on the gates surrounding the machine. If a gate
is opened the machine will shut down.
•
Laser Safety Scanners:
These are located on the front of the Edge-SS and Face-
SS. These assemblies create an invisible safety field protecting the Operator from
entering the cutting area of the machine.
•
Safety Curtain:
This is similar to the Laser Safety Scanners. This creates an invisi
-
ble curtain on all entrances to the ON-HD.
.
Summary of Contents for ON-HD
Page 4: ...KVAL ON HD Operation Manual ...
Page 8: ...KVAL ON HD Lift Manual Table of Contents ...
Page 13: ...Safety First KVAL ON HD Operation Manual 1 5 ...
Page 30: ...Safety Sign Off Sheet KVAL ON HD Operation Manual 1 22 ...
Page 54: ...About the Safety Curtain KVAL ON HD Operation Manual 2 24 ...
Page 70: ...Index Kval ON HD ...
Page 71: ......