E-Stop Light OFF
Check to see the if any E-Stop buttons are pulled out.
NOTE:
Location and quantity of E-Stop buttons varies
depending on customer need. Typical locations for E-Stop
buttons are near the Rear Access Gate and near the Tool Changer Access Gate
Stop Light OFF
Check for 110 VAC between #2 and #4 If there is voltage,
press the Start button. If no voltage, check the Stop button to
make sure it is all the way out and not stuck in, then check
the contact to make sure it is closed. If still no voltage, check
the wiring.
Start Light OFF
Push the Start button. If the Start light remains unlit,
push in the Start button and hold it in while a second
person checks for voltage between #2 and #5. If there is
110 VAC, replace the ACR relay. If there is no voltage
while the button is held in, check the wiring.
Troubleshooting Electrical Problems