Operator’s Tour
2-5
KVAL EP-1 Operation/Service Manual
C
About the Electrical Panel
The EP-1 has a Main Electrical Panel located on back section of the machine. Refer the machine's
electrical prints for in-depth information
The Main Electrical Panel:
• Supplies voltages to the machine
• Contains the PLC (Programmable
Logic Controller)
• Contains a VFD (Variable Frequency
Drive) to interact with the router motor.
Warning:
High Voltage is present in this panel at the top of the Three Phase
Input
even with the disconnect off
. If working on the panel, follow safety pro-
tocol as described in Chapter 1.
• Supplies voltage to drill by way of the
contactor and thermal overload circuit
.
Main Electrical Panel
High Voltage
Input
Fuse Bank
F1 - F8
Router VFD
Drill Thermal Over-
load Relay
110 Vac and
24VDCTerminal
24 VDC Supply
PLC
Drill Thermal Over-
load Relay
Control Transformer
230 Vac to 110 Vac
and F9
F 10
FIGURE 2- 4.
Electrical Box on the EP-1