Description of Air Input System
KVAL Operation/Service Manual
3-12
Step 2
Go to the back of the machine to start to
remove motor.
Important:
Keep one hand on the motor when
removing bolts. These two bolts and the
knurled top nut are the only securing hard
-
ware.
a. Cut any tie wraps constraining the motor
electrical wires to give range of motion
for the motor.
a.Remove the bottom bolt 3/8'' hex bolt from the back plate of the 960-3.
b.Loosen the top bolt and left lightly tightened as a safety measure to secure motor.
c.Be confident the motor is secure.
Step 3
Remove the motor from the front of the machine. Be
aware of motor electrical wires and the bit.
a.Reach around and remove the loosened 3/8''hex
nut from back of the plate. From Step 2.
b.Keeping the motor secure with your hand, loosen
the top nut.
c.Lift the motor up slowing minding the bit and the
motor electrical wires.
d.When motor is free, lay motor to the side of the
cutter head. See Step 4 for motor positioning.
Note:
This sample photograph does not
have the wires attached to the motor.
Summary of Contents for 960-3
Page 4: ...KVAL 960 3 Operation Service Manual ...
Page 28: ...Safety Sign Off Sheet 1 21 KVAL Operation Service Manual ...
Page 46: ...Description of the Light Tower KVAL Operation Service Manual 2 18 ...
Page 64: ...Appendix Collet Torque Values KVAL Operation Service Manual 3 18 ...
Page 65: ...Appendix Collet Torque Values 3 19 KVAL Operation Service Manual ...
Page 67: ...Notes ...