How to Process a Door
2-17
KVAL 700-DC Operation/Service Manual
Control Sequence Summary
The table below provides a summary of the control actions during the process of a door.
Process a Door
1.
To select the door hand. At the Sill end, simultaneously select Reset Right (RH) or
Reset Left (LH) and the Right Hands Free Button.
2.
Pull in the door; verify the header is clear so the stapler heads can come in. Have a
little wiggle room.
Action
Summary
Choose Hand
Right Hand Hands Free Reset Right or Reset Left
Bring in Side Staple Guns
(Sill End) Both Hands Free Buttons
Clamp the Head
(Head End) Both Hands Free buttons
Lower Door
(Sill End) Both Hands Free Buttons
Clamp the Door
(Sill End) Both Hands Free Buttons
Fire Staple Guns
Right Hand Hands Free Fire Button
Unclamp
(Sill End) Both Hands Free Buttons
Left Hand or Right Hand