6
ESP2000D · G
etting S
tar
ted
ESP2000D · Getting Started
AC Cable Colour Coding
If the colours referred to in the diagram don't correspond to the terminals in your plug, use the following guidelines: Connect
the blue wire to the terminal marked with an N or coloured black. Connect the brown wire to the terminal marked with an L
or coloured red. Connect the green and yellow wire to the terminal marked with an E or coloured green or green and yellow.
CAUTION: THE ESP2000D REQUIRES A GROUND CONNECTION. ALWAYS USE A GROUNDED OUTLET AND PLUG.
Safety Summary
To reduce the risk of electric shock, disconnect the amplifier from the AC mains before installing the audio cable. Reconnect
the power cord only after making all signal connections. Connect the amplifier to a two pole, threewire grounding mains
receptacle. The mains plug shall remain easy to operate. The amplifier must be powered from the same phase as other
interconnected powered units.
The receptacle must be connected to a fuse or circuit breaker. Connection to any other type of receptacle poses a shock
hazard and may violate local electrical codes. Do not allow water or any foreign object to get inside the amplifier.
Do not put objects containing liquid on or near the unit. To reduce the risk of overheating the amplifier, avoid exposing it to
direct sunlight. Do not install the unit near heatemitting appliances, such as a room heater or stove. This amplifier contains
potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains no user serviceable parts, repairs
should be performed.
Power cable color coding
Current Draw
Current Draw
115V Mode
230V, 250V
Max Long Term Continuous
20 A rms
10 A rms
Burst Current
30 A rms
15 A rms
Short Term Peak
80 A peak
40 A peak