4.  TECHNICAL SPECIFICATIONS :

Recommended use  : Indoor
Measurement range : 1'8" to 50' (0.5~15 meters)
Accuracy                  : ± 0.3% ± 1 Digit (within 6m)
Resolutions              : 0.1" (0.01m)
Laser diode type      : Red Laser 630-670 nm
Laser class              : Class 2 (Class IIIa for U.S. market)
Power supply           : 9 Volts NEDA 1604A    IEC6F22 / 6LR61
                                   alkaline type (not included)
Dimensions              : 136 (L) 

´

 61.5 (W) 

´

 44 (H) mm

Weight                      : 117g (approx.) (Excluding battery)

5.  CALCULATION RANGE :

(Calculation is made according to round up or down 2 digits
after decimal points in each reading.)

Length          : 99'11" (99.99m)

2

Area              : 999.99 sq.ft. (999.99m )
Volume         : 

3

999.99 cu.ft. (999.99m )

6.  OPERATING ENVIRONMENT :

Operating temperature  : 32ºF to 102.2ºF (0ºC to 36ºC) within still
                                        air and hard smooth target surface for
                                        accurate measurement.

7.  NOTES :

t

 When measuring between 40' to 50' / 12m to 15m, the relative

    humidity should be above 50% and target area at least 
    10ft. 

´

 10ft. (3m 

´

 3m)

t

 Inaccurate measurement may result from the following :

    1) When the battery runs out.
    2) When the measured distance is out of the specified range 
        (1'8" to 50' / 0.5 to 15m).
    3) Interference of another ultrasonic source when nearby.
    4) When the unit is not held straight and perpendicularly to the 
        target.
    5) Long narrow corridor.
    6) Irregular objects near the target.
    7) The reflected ultrasonic pulse from the target is narrow.

t

 An error message "Err" will be displayed on screen under 

    following conditions :
    1) When the measured distance or calculation result exceeded
        the specified range.
    2) When the unit is held wide angle to the target.
    3) The target surface does not provide good reflection for 
        ultrasonic pulse. (i.e. soft and irregular surface such as thick
        carpet, curtain or irregular wall paper, walls etc.)

t

 This product would lose temporal memory and reset 

    automatically under a strong electro-static environment.

Summary of Contents for KM 972M

Page 1: ...ER DISTANCE METER G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400 015 INDIA Sales Direct 022 24156638 Tel 022 24124540 24181649 Fax 022 24149659 Email kusam_meco vsnl net Website www kusame...

Page 2: ...injury 2 WARNINGS t The power of the emission of the Laser beam is less than 1mW in Class 2 less than 5mW in Class IIIa for U S market t DO NOT remove the label from the unit 3 CARE AND HANDLING t Th...

Page 3: ...he relative humidity should be above 50 and target area at least 10ft 10ft 3m 3m t Inaccurate measurement may result from the following 1 When the battery runs out 2 When the measured distance is out...

Page 4: ...c Feet Memory computation result Area L Length W Width 10 BEFORE OPERATING Slide off the battery compartment door replace fresh 9V alkaline type battery onto the battery connector then slide back the...

Page 5: ...or re start Point to the target with the unit perpendicular to the wall and get measure distance by pressing READ READ READ READ READ ADD w w Press to enter the addition mode A icon will appear on LCD...

Page 6: ...Press to enter Volume mode calculation of a room volume VOL READ READ VOL ESC ESC STORE M2 ESC w w Press to clear the store mode w Follow the above procedure to continue store Press M1 M2 M3 blink wi...

Page 7: ...MECO authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused a...

Reviews: