background image

4

IV   DISPLAY

SCAN

888.8

AL1 AL2

%Vol.

Displays the measured value

Measurement prompt

Prompt for the grade I alarming-line

Prompt for the grade II alarming-line

Unit prompt

Battery volume prompt

SCAN

AL1

AL2

%VOL.

888.8

5

V.  Operation Procedure:

1.  Enable and Disable

Press and hold the MODE ON  for 2s after the 
batteries are ready to enable it; the meter is in 
the  measuring  mode  after  it  is  enabled  and 
“SCAN”  shows  in  the  display;  press  and 
hold  the “MODE OFF”  for 2s to disable it.

2.  Backlight On/Off

You  can  switch  the  backlight  on  or  off   by 
slightly  touching  the  MODE    OFF  when  the 
instrument is in the “SCAN” mode.

3.  How to set up the alarms  for the meter

Switch  the  meter  to  the  preset  status  of  the 
level  I  alarm  by  slightly  pressing  the 
MODE  ON  button  when  the  meter  is  in  the   
“SCAN”  mode and the “ALA1” is shown on the
display.    Press    the  Position  Shift  button  and 
digit  adjusting button (0~9) to set up the data 
of the level I alarm (if you press the MODE ON
button now, you would exit the setting mode of 
level  I  alarm  and  enter  into  the  measurement 
status).  Press the MODE OFF button to save 
the setup value for the level I alarm and switch
the meter to the status for setting up the level 2
alarm  and  the  “ALA2”  shows  in  the  display.   
Press  the  Position  Shift  button  and  digit 
adjusting button (0~9) to set up the data of the 
level 2 alarming-line (if you  touch  the  MODE 
ON  button  now,  you would exit setting up the
level 2 alarm and enters into the measurement
status.

Summary of Contents for KM 5490

Page 1: ...lation Resistance Testers Earth Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Paper Grain Moisture Meter Distance Meter Digital Hand Held Temperature Indicators Digital Lux Meter Power Factor Regulator Maximum Demand Controller Digital Power Meter Gas ...

Page 2: ...ogy design and has multiple functions With highlight backlight display and acousto optic alarming it is easily configured The in built temperature compensation makes the meter measure the correct value of oxygen in the environment temperature of 10 40 C As its case is ergonomically designed it looks elegant and is easy to carry The product features Oxygen manufacturing factory Petroleum refining a...

Page 3: ...midity Storing humidity 20 80 RH relative humidity Power supply 3x1 5VAAA alkaline batteries Batteries service life about 100 hours of continuous use when the backlight is off Dimension 172 x 51 x 26 mm Weight 2 3 III PRODUCT DESCRIPTION 1 MODE ON Press hold for 2s to enable it 2 Position shifting button 3 Digit 0 9 adjust button 4 MODE OFF Press hold for 2s to disable it 5 The first alarm AL1 yel...

Page 4: ...e alarms for the meter Switch the meter to the preset status of the level I alarm by slightly pressing the MODE ON button when the meter is in the SCAN mode and the ALA1 is shown on the display Press the Position Shift button and digit adjusting button 0 9 to set up the data of the level I alarm if you press the MODE ON button now you would exit the setting mode of level I alarm and enter into the...

Page 5: ...his meter is a precise measurement apparatus To avoid damaging the meter keep it away from water and hot objects more than 60 C 2 If the meter will be measuring for a long time please turn off the backlight to save power consumption and prolong the service life of the battery 3 When is displayed the battery is fully charged the small black frame in the battery sign reduces as the battery power val...

Page 6: ...annot be Moved properly 10 14 Person may be tired and lose attention 6 10 Person may be dizzy nauseas lose consciousness and go into a coma Less than 6 Person may stop breathing and die 9 MUMBAI TEST CERTIFICATE OXYGEN ANALYSER This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications The instrument has been calibrated by using ...

Page 7: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product which is returned to a KUSAM MECO authorized service center within the warranty period 11 G 17 Bharat Indus...

Reviews: