5. BUTTON INSTRUCTION

5-1. HOLD Function

It is possible to freeze the value displayed by pressing
on the 

“HOLD”

 button.

Press the “HOLD” button again to exit the Hold mode.

5-2. MAX/MIN Function

When the “MAX/MIN” button is pressed, the meter 
enter MAX/MIN mode.

Press the button, to read MAX, MIN sequence. Press
the  button  for  1  sec.  or  more  to  exit  the  MAX/MIN 

 

mode.

When you turn the rotary switch on the Continuity
Test.

Press the 

“MAX/MIN” 

button to select Resistance

measurement,

Press the 

“MAX/MIN” 

button again to select 

continuity test with buzzer.

5-3. ZERO Function

Press “ZERO” button to enter the Zero mode, ZERO
Annunciate  will  appear  and  Zero  the  display.  The
reading is stored as reference value for subsequent
measurement.

5-4 BACKLIGHT Function

When the “    ” button is pressed, the backlight will be
turned on.
To disable the function, the button is pressed again.
The backlight will be automatically turned off about
30 seconds after it turned on.

7

6. MEASURING INSTRUCTION

6-1 ACA Measurement : With the clamp disconnected
      from any conductor, switch the function selector to
      A range.

~

Open the clamp by pressing the jaw-opening handle
and  insert  the  Cable  to  be  measured  into  the  jaw.
Close the clamp and get the reading from the LCD

panel.

Note :

Before this measurement, disconnect any test lead
with the meter for safety. 

In some cases where reading is difficult, press the
HOLD button and read the result later.

Summary of Contents for KM-2006

Page 1: ...ght Approx 270g ELECTRICAL SPECIFICATIONS All Specifications are subject to change without prior notice G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400 015 INDIA Sales Direct 022 24156638 T...

Page 2: ...aptor Transistorised Electronic Analog Digital Insulation Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared T...

Page 3: ...WARRANTY 14 KM 2006 MILLIAMP CLAMP METER...

Page 4: ...operate the tester if the body of meter or the test lead look broken Check the main function dial and make sure it is at the correct position before each measurement Do not perform resistance and con...

Page 5: ...ight 262g with battery Accessories Carrying case Batteries Test Lead Instruction Manual 3 ELECTRICAL SPECIFICATION The accuracy specification is defined as percent of reading digit At 23 5 C 80 RH V 3...

Page 6: ...nt indication ZERO indication Data hold indication Maximum indication Minimum indication Continuity test indication Measurement unit Resistance measurement indication Measurement unit 5 4 2 Descriptio...

Page 7: ...de ZERO Annunciate will appear and Zero the display The reading is stored as reference value for subsequent measurement 5 4 BACKLIGHT Function When the button is pressed the backlight will be turned o...

Page 8: ...sult from the LCD panel 8 6 2 DCA Measurement With the clamp disconnected from any conductor switch the function selector to A range Press ZERO button to enter the zero reading Open the clam by pressi...

Page 9: ...d test lead to terminal and black one to the COM terminal Connect tip of the test leads to the point where the value of the resistance is needed Read the result from the LCD panel 11 7 BATTERY CHANGIN...

Page 10: ...irs or servicing not covered in this manual should be performed only by qualified personal Periodically wipe the case with a dry cloth Do not use abrasives or solvents on these instruments 12 8 MAINTE...

Reviews: