background image

Before  open  the  meter,  disconnect  both  test  lead
& never uses the meter before the cover is closed.

To  avoid  contamination  or  static  damage,  do  not 
touch the circuit board without proper static protection.

• If the meter is not going to be used for a long time,
  take out the battery and do not store the meter in 
  high temperature or high humidity environment.

• When take current measurement, keep the cable at
  the center of the clamp will get more accurate test 
  result.

• Repairs or servicing not covered in this manual 
  should be performed only by qualified personal.

Periodically wipe the case with a dry cloth. Do not
use abrasives or solvents on these instruments.

12

8. MAINTENANCE

      WARNING !

!

CAUTION !

8-1 REMARK :

8-2 CLEANING :

TEST CERTIFICATE

MILLIAMP CLAMP METER

This  Test  Certificate  warranties  that 

the  product  has  been  inspected  and 

tested in accordance with the published 

specifications.

The instrument has been calibrated by 

using  equipment  which  has  already 

been calibrated to standards traceable 

to national standards.

MODEL NO. ___________

SERIAL NO. ___________

DATE: ___________

ISO 9001

REGISTERED

13

MUMBAI

KM 2006

QC

PASS

KUSAM-MECO

Summary of Contents for KM-2006

Page 1: ...ght Approx 270g ELECTRICAL SPECIFICATIONS All Specifications are subject to change without prior notice G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400 015 INDIA Sales Direct 022 24156638 T...

Page 2: ...aptor Transistorised Electronic Analog Digital Insulation Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared T...

Page 3: ...WARRANTY 14 KM 2006 MILLIAMP CLAMP METER...

Page 4: ...operate the tester if the body of meter or the test lead look broken Check the main function dial and make sure it is at the correct position before each measurement Do not perform resistance and con...

Page 5: ...ight 262g with battery Accessories Carrying case Batteries Test Lead Instruction Manual 3 ELECTRICAL SPECIFICATION The accuracy specification is defined as percent of reading digit At 23 5 C 80 RH V 3...

Page 6: ...nt indication ZERO indication Data hold indication Maximum indication Minimum indication Continuity test indication Measurement unit Resistance measurement indication Measurement unit 5 4 2 Descriptio...

Page 7: ...de ZERO Annunciate will appear and Zero the display The reading is stored as reference value for subsequent measurement 5 4 BACKLIGHT Function When the button is pressed the backlight will be turned o...

Page 8: ...sult from the LCD panel 8 6 2 DCA Measurement With the clamp disconnected from any conductor switch the function selector to A range Press ZERO button to enter the zero reading Open the clam by pressi...

Page 9: ...d test lead to terminal and black one to the COM terminal Connect tip of the test leads to the point where the value of the resistance is needed Read the result from the LCD panel 11 7 BATTERY CHANGIN...

Page 10: ...irs or servicing not covered in this manual should be performed only by qualified personal Periodically wipe the case with a dry cloth Do not use abrasives or solvents on these instruments 12 8 MAINTE...

Reviews: