background image

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

MODEL - KM 039F

OPERATION MANUAL

®

®

AN ISO 9001:2015 COMPANY

DIGITAL TRMS FORK

 CLAMPMETER

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638

Tel. :

 24124540, 24181649

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

®

OFFICE ADDRESS

SERVICE CENTER  

Shop no.18, 1st Floor, CIDCO Shopping 
Complex, Plot # 9, Sector-7, 
Rajiv Gandhi Marg, Sanpada, 
Navi Mumbai - 400705.

Sales Direct :

(022) 27754546

Tel. :

27750662, 27750292

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

Summary of Contents for KM 039F

Page 1: ...sters upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Maximum Demand Controller Digital Power Meter Dig...

Page 2: ...9F TABLE OF CONTENTS TITLE PAGE NO I II Cenelec Directives Safety III Special Features V Electrical Specifications VI Product Description Test Certificate IX Warranty 26 IV General Specifications VII...

Page 3: ...ak or 60 VDC These voltage levels pose a potential shock hazard to the user Do not expose this product to rain or moisture The meter is intended only for indoor use 02 Optional o er premium test probe...

Page 4: ...g s lo w voltage MAINS installation Examples are measurements on distribution boards including secondary meters circuit breakers cables bus bars junction boxes switches socket outlets stationary motor...

Page 5: ...d 2 0 to Measurement Categories CAT III 600V and CAT IV 300V AC DC 06 Overload Protections Voltage via terminals 660Vdc 920Vac rms Other functions via terminals 600Vdc Vac rms Current via Fork clamp 2...

Page 6: ...08A A 60 00A range measurement available from 0 10A 2 FORK CLAMP ACA 60 00 A 2 2 0 rdg 5dgts Range 1 Accuracy Resolution 50Hz 60Hz 200 0 A 60 00A2 3 0 rdg 5dgts 45Hz 400Hz 200 0A 0 1 V 0 1 V 0 01 A 0...

Page 7: ...752 F Accuracy 1 0 1 C 1 0 2 F 2 Type K thermocouple range accuracy not included 1 Accuracies assume meter interior has the same temperature Isothermal stage of the ambient for a correct junction volt...

Page 8: ...functions EXCEPT Fork clamp ACA and Non Contac EF Detection functions 9 ACA Magnetic eld pick up upper limit indicator below where current accuracy is speci ed 10 Antenna location symbol for Non Conta...

Page 9: ...vidual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible Do not use the meter to measure currents above the rated...

Page 10: ...nds diode The digital display shows over range If the diode is good Any other readings indicate the diode is resistive or shorted defective Beep Alert BeepLit indication When the display reading drops...

Page 11: ...t check should indicate steady ame signal of at least 2 A for a recti cation type or 1 5 m m A for an ultraviolet type 8 A for self m checking systems If a ame signal current with inadequate strength...

Page 12: ...insert the banana plug type K temperature bead probe Bkp60 with correct polarities Banana pins to type K socket adapter Bkb32 Optional purchase can be used to accept other type K probes using standar...

Page 13: ...he meter o automatically to extend battery life afteridling 32 minutes of no speci ed activities where applicable below 1 Rotary switch or push button operations 2 Signi cant measuring readings of abo...

Page 14: ...ipe the meter and the test probe assembly with a damp clothand mild detergent Do not use abrasives or solvents Allow to dry completely before operating If the meter is not to be used for periods of lo...

Page 15: ...DATA ARISING FROMANYCAUSE WHATSOEVER This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has...

Reviews: