Kusam-meco KM 039F Operation Manual Download Page 7

®

®

All Specifications are subject to change without prior notice.

TRMS DIGITAL FORK CLAMPMETER

MODEL-KM039F

Preliminary Data

An ISO 9001:2015 Company

Chhaya common data/chhaya/my documents/chhaya/backup/catlog/New catlog/2020/KM 039F Fork meter.cdr

SPECIAL FEATURES :

í

 

Fork-clamp Current measurement

í

 12mm Slim-Probe open  jaws for easy slide into tight wirings.

í

 Cx range 200.0

m

F to 2500

m

F for start & run motor capacitors.

í

 MAX/MIN Recording Mode

í

 5ms Crest (Peak-Hold) Mode.

GENERAL SPECIFICATIONS

í

 

Basic Accuracy : 

1.0% 

í

 

Sensing : 

True RMS 

í

 

Display :

 3-5/6 digits 6000 counts LCD display

í

 

Fork-Clamp opening & conductor Diameter :

 12.5mm max.

í

 

Fork-Clamp probe width :

 12mm approx.

í

 Update rate :

 5/sec nominal

í

 Operating Temperature : 

0°C to 40°C, 

í

 Relative Humidity :

 Maximum relative humidity 80% for temperature 

     upto 31°C decreasing linearly to 50% relative humidity at 40°C.

í

 Pollution degree :

 2

í

 Storage Temperature :

 -20°C to 60°C,  <80%R.H. (with battery removed).

í

 Altitude :

 Operating below 2000m

í

 Temperature Coefficient : 

nominal 0.1x (specified accuracy) / °C @ 

      (0°C ~ 18°C or 28°C ~ 40°C), or otherwise specified.

í

 

Overload Protection :

 

        Current via Fork-Clamp: 200A AC rms at <400Hz

        Voltage via terminals : 66V DC / 920V AC rms.

    

   Other functions via terminals : 600V DC / VAC rms

í

 

E.M.C. :

 Meets EN61326-1:2013

     ACA functions, in an RF field of 1V/m:

          Total Accuracy = Specified Ac 40 digits at around 87MHz

    DC

m

A and Ohm Functions, in an RF field of 1V/m:

          Total Accuracy = Specified Ac 25 digits

    Other Functions, in an RF field of 3V/m :

          Total Accuracy = Specified Ac 20 digits

í

 Low Battery Indication : 

Below Approx. 2.85V for Capacitance & Hz; 

     Below Approx. 2.5V for other functions.

í

 Auto Power Off : 

idle for 32 minutes

í

 Power Consumption : 

5

m

A Typical

í

 Power Supply : 

1.5V AAA  x 2 battery.

í

 Dimension : 

Approx.193(L)mm x 57(W)mm x 32(H)mm

í

 Weight :

 Approx. 158gm (including battery).

ACCESSORIES : 

Test leads set, Battery, User  Manual, 

Bkp60 banana-plug type-k thermocouple & carrying case.

FEATURES :

í

 

Backlight Display

í

 Non-Contact EF-Detection (NCV) with Hi/Lo Selectable Sensitivities.

í

 Probe-contact EF-Detection (Single-pole) for precise indication of live.

í

 Auto ranging for all ranges.

í

 Relative Mode.

í

 Data Hold.

í

 BeepLit feature for Diode & continuity.

í

 Intelligent Auto-Power off.

NEW

6.0KV 

Transient 

Protection

OPTIONAL ACCESSORIES : 

BKB32 banana-plug to  type-k socket plug adaptor.

THINK SAFETY

THINK 

22 FUNCTIONS  21 RANGES

 

 

 

 

Non-Contact EF-Detection (NCV)

Indication : 

Bar-graph segments & audible beep tones proportional 

                    to the field strength.

Detection Frequency :

 50/60Hz

Detection Antenna :

 Inside the top-left end of the Fork-clamp.

Probe-Contact EF-Detection (Single-pole Measurement) :  

For more precise indication of  live  wires,   such  as distinguishing 
between live and ground connections, use one single test probe to 
test  via terminal COM for direct metal contact probing to achieve 
the most distinctive indications.

Bar-Graph 

Indication

EF-H

(Hi Sensitivity)

EF-L

(Lo Sensitivity)

10V (2V~20V)

40V (8V~70V)

160V (40V~600V)

20V (4V~40V)

80V (16V~140V)

-

- -

- - -

- - - -

- - - - -

40V (10V~70V)

160V (40V~280V)

500V(160V~600V)

80V (20V~140V)

320V (80V~560V)

Typical AC voltage (Tolerance)

-40.0ºC ~ 99.9ºC

TEMPERATURE

Range

100.0ºC ~ 400ºC

-40.0ºF ~ 211.8ºF

212ºF ~ 752ºF

Accuracy

1.0% ~ 1ºC

1.0% ~ 2ºF

2) 

 Type-K thermocouple range & accuracy not included

1 )  

A c c u r a c i e s   a s s u m e   m e t e r   i n t e r i o r   h a s   t h e   s a m e  

temperature  (Isothermal  stage)  of  the  ambient  for  a  correct 
junction  voltage  compensation.  Allow  the  meter  &  the  type-K 
probe  set  to  reach  isothermal  stage  for  a  significant  change 
of ambient temperature. It can take up to an hour for changes >5°C.

09

 

10

3.000 V

±(1.5%rdg + 5dgts)

Accuracy

Resolution

Range

Test Current : 

0.3mA typically         

Open Circuit Voltage :

 < 3.5VDC typical

Beep-Alert Threshold : 

Drop across 0.850V

TM

BeepLit  ON Threshold :

 < 0.100V

Audible Indication : 

Beep sound

Visible Indication :

 LCD Backlight

TM

BEEPLIT  DIODE TESTER

Continuity Threshold :

 Between 30

W

 & 480

W

Continuity ON Response Time :

 15ms approx.

Audible Indication : Beep sound

Visible Indication : LCD Backlight

Applicability : Voltage & Non-invasion Current functions.

Accuracy      : Add ±250 digits to specified accuracy for 

                      changes >5ms in duration.

0.001 V

TM

BEEPLIT  CONTINUITY TESTER :

CREST (Peak-Hold) :

Summary of Contents for KM 039F

Page 1: ...sters upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Maximum Demand Controller Digital Power Meter Dig...

Page 2: ...9F TABLE OF CONTENTS TITLE PAGE NO I II Cenelec Directives Safety III Special Features V Electrical Specifications VI Product Description Test Certificate IX Warranty 26 IV General Specifications VII...

Page 3: ...ak or 60 VDC These voltage levels pose a potential shock hazard to the user Do not expose this product to rain or moisture The meter is intended only for indoor use 02 Optional o er premium test probe...

Page 4: ...g s lo w voltage MAINS installation Examples are measurements on distribution boards including secondary meters circuit breakers cables bus bars junction boxes switches socket outlets stationary motor...

Page 5: ...d 2 0 to Measurement Categories CAT III 600V and CAT IV 300V AC DC 06 Overload Protections Voltage via terminals 660Vdc 920Vac rms Other functions via terminals 600Vdc Vac rms Current via Fork clamp 2...

Page 6: ...08A A 60 00A range measurement available from 0 10A 2 FORK CLAMP ACA 60 00 A 2 2 0 rdg 5dgts Range 1 Accuracy Resolution 50Hz 60Hz 200 0 A 60 00A2 3 0 rdg 5dgts 45Hz 400Hz 200 0A 0 1 V 0 1 V 0 01 A 0...

Page 7: ...752 F Accuracy 1 0 1 C 1 0 2 F 2 Type K thermocouple range accuracy not included 1 Accuracies assume meter interior has the same temperature Isothermal stage of the ambient for a correct junction volt...

Page 8: ...functions EXCEPT Fork clamp ACA and Non Contac EF Detection functions 9 ACA Magnetic eld pick up upper limit indicator below where current accuracy is speci ed 10 Antenna location symbol for Non Conta...

Page 9: ...vidual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible Do not use the meter to measure currents above the rated...

Page 10: ...nds diode The digital display shows over range If the diode is good Any other readings indicate the diode is resistive or shorted defective Beep Alert BeepLit indication When the display reading drops...

Page 11: ...t check should indicate steady ame signal of at least 2 A for a recti cation type or 1 5 m m A for an ultraviolet type 8 A for self m checking systems If a ame signal current with inadequate strength...

Page 12: ...insert the banana plug type K temperature bead probe Bkp60 with correct polarities Banana pins to type K socket adapter Bkb32 Optional purchase can be used to accept other type K probes using standar...

Page 13: ...he meter o automatically to extend battery life afteridling 32 minutes of no speci ed activities where applicable below 1 Rotary switch or push button operations 2 Signi cant measuring readings of abo...

Page 14: ...ipe the meter and the test probe assembly with a damp clothand mild detergent Do not use abrasives or solvents Allow to dry completely before operating If the meter is not to be used for periods of lo...

Page 15: ...DATA ARISING FROMANYCAUSE WHATSOEVER This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has...

Reviews: