Küppersbusch KD 965.1 Instructions For Use And Installation Instructions Download Page 7

Installation 

 

Danger!

 The cooker hood may only be installed and the electrics

connected by a qualified technician.
Pay attention to the notes on safety on page 13!

 

Danger! 

For all installation and maintenance work the cooker hood

must be disconnected from the power supply. 
As the mains plug is no longer accessible after installation, 
you must switch off the relevant household fuse.

Scope of delivery

The hood is delivered in a cardboard box. The basic features are the same
for all versions.

Basic features 

Chimney, drilling template, fastening material

Glass fume screen with motor and metal fat filter

Recirculating air deflector, connection element for the recirculation mode 

KDEM 965.1

The motor is supplied separately for hoods with an external motor.

Dimensions for installation

Installation preconditions 

Please also observe the notes on extraction paths on page 20.

Walls suitable for mounting

The cooker hood can be mounted directly on the wall or on a steel rear panel.

The fitter is always responsible for selecting the correct fastening material.
The fastening method must be suitable for the weight of the hood.

The enclosed dowels and screws are suitable for walls made of perfora-
ted bricks or concrete bricks which are  20 mm thick. 

For solid concrete walls you must use special concrete dowels from a
specialist store.

For solid wooden walls you must use wood screws of sufficient thick-
ness and length.

Electric connection   

The hood is fitted with a normal mains plug and there should therefore be a
socket outlet (230 V AC) near the point of installation.

Recirculation mode

There are no other preconditions for the customer. 

Extraction path to the rear

There must be an exhaust channel
150 mm in diameter through the
wall inside the chimney surface.

Extraction path upwards 

There must be an exhaust channel

150 mm in diameter inside the chimney 

surface in the room ceiling above 
the installation point of the hood.

Mounting a steel rear panel (optional) 

Insert the bottom edge of the rear panel behind the worktop or the built-in
hob. The rear panel must rest on the worktop.

With a telescopic rear panel set the length you want. 

Make sure that the hood is mounted at least 650 mm above the hob.

Mark the drill holes.

Drill the holes and insert dowels.

Guide the power cable and, if provided, the control line of the external mo-
tor through the opening in the rear panel and screw on the panel.

Extraction mode

Recirculation

KD 965.1 / KDEM 965.1

17

Summary of Contents for KD 965.1

Page 1: ... for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 965 1 KDEM 965 1 537 517 G61 ...

Page 2: ...s and functions For operating your cooker hood For operating the hood with stoves and heating appliances with a naked flame General advice 13 Your appliance at a glance 14 Using the hood 14 Before using your appliance for the first time Switching the lighting On Off Switching on the ventilation Changing the ventilation setting Switching the ventilation off Switching on the delayed stop time Cleani...

Page 3: ... used simultaneously in rooms where a negative pressure of 0 04 mbar is not exceeded This ensures that the fumes from the stove are not sucked back into the room This can be achieved if there are non airtight openings in windows and doors ventilation wall boxes supplying extracting air or other technical devices e g interlock devices so that a sufficient supply of combustion air can flow back into...

Page 4: ...he hood in the settings 2 to 4 after 10 minutes After switching the hood on press the respective setting button a se cond time With the timer activa ted the control light of the setting selected flashes Press the button 0 1 to switch off the hood before the time lapses Cleaning interval for the fat filters After about 30 hours of operation all the control lights flash at the same time to remind yo...

Page 5: ...re with the holders Insert both filters again To this end insert the two brackets of one cover into the openings provided in the lamp holder press the filter upwards and then push inwards until it is firmly in position If the control lights still flash when the hood is used for the first time af ter cleaning press one of the lower three buttons The counter for the operating hours is then reset to ...

Page 6: ... defective Pull out plug or switch off fuse Call Customer Service Halogen lighting does not work Lamp defective Replace lamp LED does not work LED defective Call Customer Service Performance of the cooker hood is re duced Filters very clogged Replace filters Several LEDs flash Not a defect see Cleaning the metal fat filters Rating label The rating label can be seen when you have removed the fat fi...

Page 7: ...enclosed dowels and screws are suitable for walls made of perfora ted bricks or concrete bricks which are 20 mm thick For solid concrete walls you must use special concrete dowels from a specialist store For solid wooden walls you must use wood screws of sufficient thick ness and length Electric connection The hood is fitted with a normal mains plug and there should therefore be a socket outlet 23...

Page 8: ...y The chimney consists of two parts The upper part has ventilation slits the lower part recesses for the control buttons The recesses for the control but tons must always be at the bot tom The chimney parts can be pulled apart and pushed together again as required Recirculation mode The ventilati on slits must be at the top Extraction mode The ventilation slits must be at the bottom so that they a...

Page 9: ...he control buttons protrude slightly forwards out of the chimney Inserting the metal fat filters Before you install the filters again you should read off the serial number and the model designation on the rating label and enter them on page 16 Only appliances with recirculation mode Place an activated charcoal filter in each filter cover and secure with the holders All appliances Mount both filter...

Page 10: ...pe must not exceed 2 5 m The pipe must be heat insulated or an air trap seal must be installed Extraction into an existing exhaust shaft The exhaust air must only be introduced into an existing exhaust shaft if this is insulated against damp and is not already used for fuel purposes Have the chimney sweep responsible approve the use of the shaft Please note If the extraction channel is led through...