![Küppersbusch KD 965.1 Instructions For Use And Installation Instructions Download Page 7](http://html.mh-extra.com/html/kuppersbusch/kd-965-1/kd-965-1_instructions-for-use-and-installation-instructions_2010599007.webp)
Installation
Danger!
The cooker hood may only be installed and the electrics
connected by a qualified technician.
Pay attention to the notes on safety on page 13!
Danger!
For all installation and maintenance work the cooker hood
must be disconnected from the power supply.
As the mains plug is no longer accessible after installation,
you must switch off the relevant household fuse.
Scope of delivery
The hood is delivered in a cardboard box. The basic features are the same
for all versions.
Basic features
Chimney, drilling template, fastening material
Glass fume screen with motor and metal fat filter
Recirculating air deflector, connection element for the recirculation mode
KDEM 965.1
The motor is supplied separately for hoods with an external motor.
Dimensions for installation
Installation preconditions
Please also observe the notes on extraction paths on page 20.
Walls suitable for mounting
The cooker hood can be mounted directly on the wall or on a steel rear panel.
The fitter is always responsible for selecting the correct fastening material.
The fastening method must be suitable for the weight of the hood.
The enclosed dowels and screws are suitable for walls made of perfora-
ted bricks or concrete bricks which are 20 mm thick.
For solid concrete walls you must use special concrete dowels from a
specialist store.
For solid wooden walls you must use wood screws of sufficient thick-
ness and length.
Electric connection
The hood is fitted with a normal mains plug and there should therefore be a
socket outlet (230 V AC) near the point of installation.
Recirculation mode
There are no other preconditions for the customer.
Extraction path to the rear
There must be an exhaust channel
150 mm in diameter through the
wall inside the chimney surface.
Extraction path upwards
There must be an exhaust channel
150 mm in diameter inside the chimney
surface in the room ceiling above
the installation point of the hood.
Mounting a steel rear panel (optional)
Insert the bottom edge of the rear panel behind the worktop or the built-in
hob. The rear panel must rest on the worktop.
With a telescopic rear panel set the length you want.
Make sure that the hood is mounted at least 650 mm above the hob.
–
Mark the drill holes.
–
Drill the holes and insert dowels.
Guide the power cable and, if provided, the control line of the external mo-
tor through the opening in the rear panel and screw on the panel.
Extraction mode
Recirculation
KD 965.1 / KDEM 965.1