18
Impor
tant:
Ne
ver use sharp metal tools to scrape off fr
ost
fr
om the e
v
aporator as y
ou could dama
g
e it.
Do not use a maec
hanical de
vice or an
y ar
tificial
means to speed up the tha
wing pr
ocess other
than those recommended b
y the man
ufacturer
.
A temperature rise of the fr
oz
en f
ood pac
ks,
during defr
osting,
ma
y shor
ten their saf
e stora
g
e
lif
e
.
Interior light
The light b
ulb inside the refr
iger
ator compar
tment
can be reached as f
ollo
ws:
- unscre
w the light co
v
er secur
ing scre
w
.
- unhook the mo
ving par
t as sho
wn in the figure
.
If the light does not come on when the
door is open,
c
hec
k that it is scre
wed into place
pr
operl
y
.
If it still does not light up,
c
hang
e the
b
ulb.
The rating is sho
wn on the light b
ulb co
ver
.
D
41
1
Defr
osting
F
rost is automatically eliminated from the e
v
apor
ator
of the refr
iger
ator compar
tment e
v
er
y time the motor
compressor stops
, dur
ing nor
mal use
.The defrost
w
ater dr
ains out through a trough into a special
container at the bac
k of the appliance
, o
v
er the
motor compressor
, where it e
v
apor
ates
.
It is impor
tant to periodicall
y c
lean the defr
ost
water drain hole in the mid
dle of the refrig
erator
compar
tment c
hannel to pre
vent the water
o
verflo
wing and dripping onto the f
ood inside
.
Use the special c
leaner pr
o
v
ided,
whic
h y
ou will
find alread
y inser
ted into the drain hole
.
The freez
er compar
tment, ho
w
e
v
e
r, will become
prog
ressiv
ely co
v
ered with frost.
This should be
remo
v
ed with a plastic scr
aper , whene
v
er the
thic
kness of the frost e
xceeds 4 mm.
Dur
ing this
oper
ation it is not necessar
y to s
witch off the po
w
e
r
supply or to remo
v
e the f
oodstuffs
.
Ho
w
e
v
e
r, when the ice becomes v
er
y thic
k on the
inner liner
, complete defrosting should be carr
ied out
and it is advisab
le to carr
y out this oper
ation when
the appliance is empty
.
T
o
carr
y out complete defrosting of the freez
er
compar
tment
proceed as f
ollo
ws:
1.
pull out the plug from the w
all soc
k
et or tur
n the
ther
mostat knob to the «O» setting;
2.
remo
v
e an
y stored f
ood, wr
ap it in se
v
e
ral la
y
e
rs
of ne
wspaper and put it in a cool place;
3.
lea
v
e the door open, place a basin on the top
shelf of the refr
iger
ator compar
tment under the
dr
ain hole
, remo
v
e the plugas sho
wn in the
figure;
4.
when defrosting is completed, dr
y the inter
ior
thoroughly and refit the plug;
5.
tur
n the ther
mostat knob bac
k to the required
setting or replace the plug in the po
w
er soc
k
et.
After letting the appliance r
un f
or at least half an
hour
, replace the pre
viously remo
v
ed f
ood into
the compar
tment.
PR151
D037
19
CUST
OMER SER
VICE AND SP
ARE P
AR
T
S
If the appliance is not functioning proper
ly
, chec
k
that:
•
the plug is fir
mly in the w
all soc
k
e
t and the mains
po
w
er s
witch is on;
•
there is an electr
icity supply (find out b
y plugging
in another appliance);
•
the ther
m
ostat knob is in the correct position.
•
If there are w
ater drops on the bottom of the
cabinet, chec
k that the defrost w
ater dr
ain
opening is not obstr
ucted (see
“Defrosting”
section).
•
If y
our appliance is still not w
or
king proper
ly after
making the abo
v
e chec
ks
, contact the nearest
ser
vice centre
.
T
o obtain f
ast ser
vice
, it is essential that when y
ou
apply f
or it y
ou specify the model and ser
ial n
umber
of y
our appliance which can be f
ound on the
guar
antee cer
tificate or on the r
ating plate located
inside the appliance
, on the bottom left-hand side
.
INST
ALLA
TION
Location
The appliance should be installed w
ell a
w
a
y from
sources of heat such as r
adiators
, boilers
, direct
sunlight etc.
Electrical connection
Bef
ore plugging in, ensure that the v
oltage and
frequency sho
wn on the ser
ial n
umber plate
correspond to y
our domestic po
w
er supply
.V
oltage
can v
ar
y b
y ±6% of the r
ated v
oltage
.
F
or oper
ation with diff
erent v
oltages
, a suitab
ly siz
ed
auto-tr
ansf
or
mer m
ust be used.
The appliance m
ust be ear
thed.
The po
w
er supply cab
le plug is pro
vided with a
contact f
or this pur
pose
.
If the domestic po
w
er supply soc
k
et is not ear
thed,
connect the appliance to a separ
ate ear
th in
compliance with current regulations
, consulting a
specialist technician.
The Man
ufacturer dec
lines all responsibility if
the abo
ve saf
ety precautions are not obser
ved.
This appliance complies with the f
ollo
wing
E.E.C
.
D
irectiv
es:
- 87/308 EEC
of 2/6/87 relativ
e to r
adio interf
erence
suppression.
- 73/23 EEC
of 19.2.73 (Lo
w
V
oltage Directiv
e) and
subsequent modifications;
- 89/336 EEC
of 3.5.89 (Electromagnetic
Compatibility Directiv
e) and subsequent
modifications
.
ATTENTION!
It m
ust be possib
le to disconnect the appliance from
the mains po
w
er supply;
the plug m
ust theref
ore be
easily accessib
le after installation.
Building-in instructions
Installation par
ts
53
0
1219
1233
1220
1221-1227
540
50
Dimension
F
o
r saf
ety reasons
, minim
um v
entilation m
ust be as
sho
wn in Fig.
Attention:
keep ventilation openings c
lear of
obstruction.
C