background image

30 

Pan detection 

The pan detection ensures a perfect safety. The induction doesn’t work: 

  If there is no pan on the heating zone or if this pan is not adapted to the induction. In this 

case  it  is  impossible  to  increase  the  power  and  the  display  shows  [  U  ].  This  symbol 
disappears when a pan is put on the heating zone. 

  If the pan is removed from the heating zone the operation is stopped. The display shows   

[  U  ].  The  symbol  [  U  ]  disappears  when  the  pan  is  put  back  to  the  heating  zone.  The 
cooking continues with the power level set before. 

After use, switch the heat element off: don’t let the pan detection [ U ] active. 

Residual heat indication 

After the switch off of a heating zone or the complete stop of the hob, the heating zones are still 
hot and indicates [ H ] on the display. 
The symbol [ H ] disappears when the heating zones may be touched without danger. 
As far as the residual heat indicators are on light, don’t touch the heating zones and don’t put any 
heat sensitive object on them. There are risks of burn and fire. 

Booster function 

The booster function [ P ] grants a boost of power to the  selected heating zone. 
If this function is activated the heating zones works during 5 minutes with an ultra high power. 
The booster is foreseen for example to heat up rapidely big quantities of water, like nuddles cooking. 

  Start up / Stop the booster  function : 

Action 

 

 

 

Control panel 

 

 

 

Display 

Zone selection 

 

 

Press key [ 

 ] 

 

 

 

[ 0 ] 

Increase power 

 

 

Press key [ + ] 

 

 

 

[ 1 ] to [ 9 ] 

Start up the booster  

 

Press key [ + ] 

 

 

 

[ P ] during 5 min 

Stop the booster 

 

 

Press key [ - ] 

 

 

 

[ 9 ] 

  Power management: 

When it comes to the power, the cooking zones are running by pairs and cannot exceed an overall 
maximum of power. If the selected heating levels for both zones exceed the maximum available 
amount of power, the powermanagement function is automatically reducing the power from one of 
these zones. The display of this zone is first blinling ; the level is then automatically reduced to the 
highest suitable position. 
 
Heating zone selected 

 

The other heating zone:  (example: power level 9) 

[ P ] is displayed 

 

 

[ 9 ] goes to [ 8 ] and blinks 

 
Note: if the two left cooking zones are used at the maximal power level, the middle cooking zone 
is unusable.

Summary of Contents for EKI9652.1F

Page 1: ...BEDIENUNGSANWEISUNG mit Montageanweisungen Instructions for use and installation Instructions d utilisation et d installation EKI9652 1F...

Page 2: ...ROL PANEL 28 USE OF THE APPLIANCE 28 DISPLAY 28 VENTILATION 28 STARTING UP AND APPLIANCE MANAGEMENT 29 BEFORE THE FIRST USE 29 INDUCTION PRINCIPLE 29 SENSITIVE TOUCH 29 STARTING UP 29 PAN DETECTION 30...

Page 3: ...plate can not be used as freestanding or as working surface The appliance must be grounded and connected conforming to local standards Do not use any extension cable to connect it The appliance can n...

Page 4: ...children without supervision Metallic objects such as knives forks spoons and lids should not be placed on the surface since they can get hot Precautions not to damage the appliance Raw pan bottoms o...

Page 5: ...to avoid the possibility of electric shock If the supply cor dis damaged it must be replaced by a cable or special set available by the manufacturer or his after sale service Other protections Note s...

Page 6: ...177 3 Wh kg Middle heating zone 279 mm Minimum detection 110 mm Nominal power 2300 W Booster power 3000 W Standardised cookware category D Energy consumption ECcw 171 6 Wh kg Rear right heating zone...

Page 7: ...ed L Locking Control panel locking II Stop Go The hob is in pause Keep warm Maintain automatically of 70 C Bridge 2 cooking zones are combined Ventilation The cooling system operates continuously He s...

Page 8: ...atically the size of the pan With a too small diameter the pan doesn t work This diameter is varying in function of the heating zone diameter If the pan is not adapted to the induction hob the display...

Page 9: ...em There are risks of burn and fire Booster function The booster function P grants a boost of power to the selected heating zone If this function is activated the heating zones works during 5 minutes...

Page 10: ...y 0 To select Timer Press key during 3s The remaining time To stop the Timer Press key 00 then stops If several timers are activated repeat the process Automatic stop at the end of the cooking time As...

Page 11: ...c cooking Action Control panel Display Zone selection Press key 0 Stop the automatic cooking Press key II 0 9 Bridge This function allows to use 2 cooking zones at same time with the same features as...

Page 12: ...warm function The recall procedure is following Press the key Then press the key II within 6 seconds The precedent settings are activated Keep Warm This function allows to reach and maintain automatic...

Page 13: ...ouble beep Registering validation If no memorising is made within timer validation the electronics returns in cooking position To activate the memory program for a cooking zone Action Control panel Di...

Page 14: ...induction heating zone set at level 9 This water must heat in a few seconds A magnet stucks on the bottom of the pan Certain pans can make noise when they are placed on an induction cooking zone This...

Page 15: ...thoroughly Highly corrosive or abrasive detergents and cleaning equipment likely to cause scratches must be absolutely avoided Do not ever use any steam cleaner or pressure washer Do not use any obje...

Page 16: ...y is released or cleaned The control panel displays E2 or EH The hob is overheated let it cool and then turn it on again The control panel displays E3 The pan is not adapted change the pan The control...

Page 17: ...ace on either side There may be a wall at the rear and tall units or a wall at one side On the other side however no unit or divider must stand higher than the hob The piece of furniture or the suppor...

Page 18: ...re not to obstruct the openings foreseen in the casing of the hob These holes are necessary for an efficient ventilation of the appliance Avoid any excessive heating under the cooktop eg related to a...

Page 19: ...ge between terminal 1 and 2 Attach the earth to the terminate earth the neutral N to terminal 4 the Phase L to one of the terminals 1 or 2 Biphase 400V 2P N Attach the earth to the terminate earth the...

Page 20: ...19828 0...

Reviews: